13. DISPLAY MESSAGES
SELECT BATTERY TYPE (No LED lit) – Waiting for user to select battery type.
The charger will remember the battery type selected.
LITHIUM ION BATTERY-PRESS AGAIN FOR LEAD-ACID (No LED lit) –Charging
will begin for lithium-ion battery type. Press again to change to lead-acid battery type.
LEAD-ACID BATTERY-PRESS AGAIN FOR LITHIUM ION (No LED lit) –Charging
will begin for lead-acid battery type. Press again to change to lithium-ion battery type.
CONNECT CLAMPS TO LITHIUM ION BATTERY (No LED lit) Plugged into the AC
outlet, and lithium-ion battery type is selected, without the clamps connected to a battery.
CONNECT CLAMPS TO LEAD ACID BATTERY (No LED lit) – Plugged into the AC
outlet, and lead-acid battery type is selected, without the clamps connected to a battery.
WARNING CLAMPS REVERSED (No LED lit) – Plugged into the AC outlet and
the clamps are connected backwards to a battery.
ANALYZING LEAD-ACID BATTERY (or) ANALYZING LITHIUM ION BATTERY
(Green LED lit) – Plugged into the AC outlet, and when rst connected correctly to a battery.
CHARGING 12V – xx% (Green LED lit) – Plugged into the AC outlet and correctly
connected to a discharged 12V battery.
FULLY CHARGED AUTO MAINTAINING (Green LED pulsing) – Plugged into the
AC outlet and correctly connected to a fully charged battery.
CHARGE ABORTED-BAD BATTERY (Green LED ashing) –
Circumstances that could cause an Abort situation during charging:
The battery is severely sulfated or has a shorted cell and can’t reach a full charge.
The battery is too large or there is a bank of batteries and it doesn’t reach full
charge within a set time period.
Circumstances that could cause an Abort situation during maintain:
The battery is severely sulfated or has a weak cell and will not hold a charge.
There is a large draw on the battery and the charger has to supply its maximum
maintain current for a 12 hour period to keep the battery at full charge.
BATTERY DISCONNECTED (No LED lit) – After charging has begun, the charger
has lost its connection to the battery.