The HYDRUS operates in water temperatures between 34 °F
and 122 °F.
6.1 Installing the HYDRUS
Installation location
Maintain sucient distance between the HYDRUS and possible
sources of electromagnetic interference (switches, electric motors,
uorescent lamps, etc.).
Calming sections upstream and downstream of the HYDRUS are not
necessary.
Avoid a mounting position where air bubbles may accumulate in the
HYDRUS.
Preparations
If the water is dirty, install a dirt trap in the feed line upstream of
the HYDRUS.
Flush the pipes thoroughly before installing the HYDRUS.
Mounting
Close the shuto valves upstream and downstream of the water me-
ter or spacer and release the pressure in the pipeline.
Remove the spacer or old water meter.
Remove old washer, clean sealing faces and install ber gaskets.
Install the HYDRUS so that the arrow on the housing points with in
the direction of the water ow.
Install the HYDRUS in the pipeline, avoid mechanical stresses.
Protect the HYDRUS against pressure surges in the pipeline.
-7-
HYDRUS
English