SM – 100 Operation Manual
69
3.11 Vender File
Vender file is used for programming names of operators. Maximum 16 characters can be entered per
Vender name. A programmed Vender number can be assigned to a preset key. The Vender Number or
Name (Depend on Spec 21 setting) will be printed on the label, if selected label format with print area
for Vender Number and the programmed Vender name can be printed on receipt when SPEC 21 set
to NAME.
3.11.1 Program Vender File
OPERATION
DISPLAY
REMARK
PT kg
/kg
[MODE][MODE]
[MODE]
S1
PLU FILE
Enter S mode.
Lamp S turns on.
[7] or [] six times
S7
VENDER FILE
Select Vender file
programming mode.
[*] S7.0 CLERK 0 NO SET
Enter Vender File
programming mode.
[1][*] S7.1 CLERK 1 NAME 0
Select vender key.(Ex. V1)
Program operator name for
Vender 1.
[M][I][K][E] S7.1 CLERK MIKE NAME 4
Enter operator name for
V1.(Ex. “MIKE”)
[PLU] S7
VENDER FILE
Store Vender File V1,back to S
mode.
Note1: V1 – V99 can be programmed