EasyManua.ls Logo

Digikeijs DR4088CS

Digikeijs DR4088CS
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DR4088LN-CS / GND / OPTO 2021-04-21
P 1
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
DR 4088LN-xx
Instrucon manual
(2021-04-21)
© Copyright 2005 – 2018 digikeijs, the Netherlands. All
rights reserved. No informaon, images or any part of
this document may be copied without the prior wrien
permission of Digikeijs.

Other manuals for Digikeijs DR4088CS

Question and Answer IconNeed help?

Do you have a question about the Digikeijs DR4088CS and is the answer not in the manual?

Digikeijs DR4088CS Specifications

General IconGeneral
ManufacturerDigikeijs
Product NumberDR4088CS
TypeFeedback module
InterfaceLocoNet
Number of Inputs16
Current DetectionYes

Summary

General Information and Legal

Warranty Conditions

Details the 24-month manufacturer's warranty and conditions for invalidation.

Legal Information

States reservation of rights for changes, non-binding data, and copyright protection.

Product Overview

General Product Information

The DR4088LN-xx is a 16-input feedback module connectable via LocoNet.

Technical Specifications

Details connection terminal cross-sections and electrical specifications for different versions.

Hardware Overview

Components and Connectors

Lists and explains numbered hardware features like feedback connections, LEDs, buttons, and LocoNet/S88 connectors.

Programming Procedures

Programming without further DR4088 on S88 N

Details how to program the DR4088LN-xx using the DR5000.

Programming with DR5000

Step-by-step guide to programming the DR4088LN-xx with a DR5000 central unit.

Programming with Control Panel or App

Explains programming the DR4088LN-xx using various control panels or mobile applications.

Programming with Chained DR4088 Modules

Describes how to program the DR4088LN-xx when chaining multiple DR4088 modules.

Programming Chained Modules with Control Panel or App

Explains programming DR4088LN-xx with chained DR4088 units using control panels or apps.

Resetting and Connection Examples

Resetting the DR4088 LN-xx

Explains that the DR4088LN-xx has no factory reset, but start address and feedback count can be reset.

Connection Examples

Introduces connection examples for various feedback scenarios using the DR4088LN-xx.

Connection Examples

DR4088 LN-CS; 2-wire track

Illustrates connecting DR4088LN-CS feedback modules to a DR5000 for 2-wire track systems.

DR4088 LN-CS and DR5033 Booster; 2-wire track

Shows how to connect DR4088LN-CS modules and a DR5033 Booster for 2-wire track setups.

DR4088 LN-OPTO; Hall sensors, 3-wire track

Demonstrates connecting DR4088LN-OPTO modules with Hall sensors for 3-wire track systems.

DR4088 LN-OPTO; switch track, 2-wire track

Illustrates connecting DR4088LN-OPTO modules with switches or reed contacts for 2-wire track.

DR4088 LN-GND; switches, buttons, reed contacts

Shows connecting DR4088LN-GND modules with switches, buttons, or reed contacts for 3-wire track.

Related product manuals