DR4088LN-CS / GND / OPTO 2021-04-21
P 1
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
DR 4088LN-xx
Instrucon manual
(2021-04-21)
© Copyright 2005 – 2018 digikeijs, the Netherlands. All
rights reserved. No informaon, images or any part of
this document may be copied without the prior wrien
permission of Digikeijs.

Other manuals for Digikeijs DR4088CS

Question and Answer IconNeed help?

Do you have a question about the Digikeijs DR4088CS and is the answer not in the manual?

Summary

General Information and Legal

Warranty Conditions

Details the 24-month manufacturer's warranty and conditions for invalidation.

Legal Information

States reservation of rights for changes, non-binding data, and copyright protection.

Product Overview

General Product Information

The DR4088LN-xx is a 16-input feedback module connectable via LocoNet.

Technical Specifications

Details connection terminal cross-sections and electrical specifications for different versions.

Hardware Overview

Components and Connectors

Lists and explains numbered hardware features like feedback connections, LEDs, buttons, and LocoNet/S88 connectors.

Programming Procedures

Programming without further DR4088 on S88 N

Details how to program the DR4088LN-xx using the DR5000.

Programming with DR5000

Step-by-step guide to programming the DR4088LN-xx with a DR5000 central unit.

Programming with Control Panel or App

Explains programming the DR4088LN-xx using various control panels or mobile applications.

Programming with Chained DR4088 Modules

Describes how to program the DR4088LN-xx when chaining multiple DR4088 modules.

Programming Chained Modules with Control Panel or App

Explains programming DR4088LN-xx with chained DR4088 units using control panels or apps.

Resetting and Connection Examples

Resetting the DR4088 LN-xx

Explains that the DR4088LN-xx has no factory reset, but start address and feedback count can be reset.

Connection Examples

Introduces connection examples for various feedback scenarios using the DR4088LN-xx.

Connection Examples

DR4088 LN-CS; 2-wire track

Illustrates connecting DR4088LN-CS feedback modules to a DR5000 for 2-wire track systems.

DR4088 LN-CS and DR5033 Booster; 2-wire track

Shows how to connect DR4088LN-CS modules and a DR5033 Booster for 2-wire track setups.

DR4088 LN-OPTO; Hall sensors, 3-wire track

Demonstrates connecting DR4088LN-OPTO modules with Hall sensors for 3-wire track systems.

DR4088 LN-OPTO; switch track, 2-wire track

Illustrates connecting DR4088LN-OPTO modules with switches or reed contacts for 2-wire track.

DR4088 LN-GND; switches, buttons, reed contacts

Shows connecting DR4088LN-GND modules with switches, buttons, or reed contacts for 3-wire track.

Overview

The DR4088LN-xx is a versatile feedback module designed for model railway enthusiasts, enabling seamless integration with a control panel via LocoNet®. This module is equipped with 16 feedback inputs, allowing for comprehensive monitoring of your model railway layout. It comes in three distinct versions to cater to various track configurations and sensor types: the CS version (current sensor 2-wire track), the OPTO version (for connecting reed contacts and 3-wire track signals to track ground), and the GND version (for 3-wire tracks).

Function Description:

The primary function of the DR4088LN-xx is to provide feedback from your model railway layout to your central control unit. This feedback is crucial for automated operations, track occupancy detection, and precise train control. By detecting the presence of trains or the activation of sensors, the module sends signals back to the control panel, allowing the system to react accordingly. For instance, in the CS version, current sensors detect a train's presence on a 2-wire track by monitoring current draw. The OPTO version offers flexibility by supporting reed contacts and 3-wire track signals, providing optical isolation for enhanced reliability. The GND version is specifically designed for 3-wire track systems, although it comes with an important caveat regarding its use with certain central units.

The module operates within the LocoNet® universal bus system, which supports a maximum of 2048 feedback addresses. This extensive addressing capability allows for very large and complex layouts to be monitored effectively. The addresses are stored directly within the feedback module, simplifying setup and ensuring consistent operation. LocoNet®'s flexible topology supports tree, star, or bus (line) networks, and even combinations thereof, offering considerable freedom in designing your layout's wiring. However, it's important to note that a ring structure is not permitted within the LocoNet® framework.

Usage Features:

Setting up and programming the DR4088LN-xx is a straightforward process, whether you're using a DR5000 central unit or another control panel or app. The module's programming involves assigning a start address and specifying the number of feedback units it manages. This is done by sending specific turnout commands to the module while it's in programming mode.

To program the module, you first connect it to your central unit. If you're using a DR5000, you'll open the DR5000 Tool. The programming sequence begins by pressing the programming button on the DR4088LN-xx, which causes a green LED to flash, indicating it's ready for input. You then assign the start address by switching a turnout address (e.g., 1) once, typically by activating either the red or green state. The green LED will then change its flashing pattern, signaling that the module is now expecting the number of feedback signals. You send this information by again using a turnout command corresponding to the desired number of feedback units. For instance, if no other DR4088 (S88) modules are connected, the default number of feedback units is 16. Once these two steps are completed, the DR4088LN-xx automatically exits programming mode, having been successfully configured with its start address and the number of feedbacks.

When integrating the DR4088LN-xx with additional DR4088 modules on the S88(N) connection, the programming process is similar but accounts for the larger number of feedback contacts. A single DR4088LN-xx can manage up to 15 additional DR4088 modules connected via S88, resulting in a maximum of 256 feedback contacts. In this scenario, the turnout commands sent during programming will correspond to the total number of feedback units across all connected modules (e.g., 32 for one DR4088, 48 for two, 64 for three, and so on).

The hardware overview of the DR4088LN-xx highlights its user-friendly design. It features clearly labeled connections for feedback inputs (1 to 8 and 9 to 16), common "C" connections for detector groups, and LocoNet® connectors for bus integration. A programming button facilitates easy entry into programming mode. LED indicators provide visual feedback on the module's status: a green LED flashes when power is supplied and signals different programming levels, while a red LED flashes during load or activity at the S88N connection. S88N In connectors are also present for daisy-chaining multiple S88 modules.

Maintenance Features:

A key aspect of the DR4088LN-xx's design is its simplicity regarding maintenance and resetting. Unlike some other devices, the DR4088LN-xx does not have a function to reset to factory settings. This is because its only configurable parameters are the start address and the number of response addresses. Therefore, a full factory reset is deemed unnecessary.

If you need to "reset" the module to its basic settings, you simply reprogram it with the desired start address (typically 1) and the default number of feedbacks (16). This process, as described in the programming section, effectively reconfigures the module to a known state without requiring a dedicated reset button or complex procedure. This design choice emphasizes ease of use and reduces potential complications associated with accidental resets.

Important Considerations:

A critical note for users of the DR4088LN-GND version, especially when paired with DR50xx central units, concerns 3-wire operation. Due to the H-bridge (track output) in the DR50xx, feedback devices in the DR4088LN-GND version must not be used against track ground, as is typically done with 3-wire tracks. Failing to observe this warning will inevitably lead to the destruction of the DR50xx central unit. If you are operating a 3-wire track system with a DR50xx and require feedback against track ground, the DR4088LN-OPTO version should be used instead, as it provides the necessary isolation to prevent damage.

The DR4088LN-xx is a robust and flexible solution for integrating feedback into your model railway, offering clear programming procedures and a design focused on reliable operation within the LocoNet® ecosystem.

Digikeijs DR4088CS Specifications

General IconGeneral
ManufacturerDigikeijs
Product NumberDR4088CS
TypeFeedback module
InterfaceLocoNet
Number of Inputs16
Current DetectionYes