5. If the V-Switch is too sensitive, press the right Up Footswitch to raise the threshold (range
is 0-200). Keep testing the V-Switch sensitivity and adjust the threshold until it only engages
when you want it to (too sensitive a setting will lead to the V-Switch falsely triggering on or
off when using the Expression Pedal).
6. When the V-Switch sensitivity is set to your satisfaction, press both Up/Down Footswitch-
es simultaneously to exit.
Note: If the Display shows ERROR, an error has occurred and steps 2 through 5 should be
repeated.