1. Long press the SET button until the appears and the ashes.
2. Short press the UP or DOWN button and there will be a ashing,
then press the SET button to select the temperature.
3. Press UP or DOWN to adjust the RUN temperature you required.
4. Short press SET button to set STOP temperature and next value.
5. Long press SET button to save and exit.
Set humidication mode:
To set the RV(RUN value) < SV(STOP value), the system will be in
humidication mode and the will appear on the
display. When PV(Measuring temperature) < RV, the green indicator of
HUMIDITY will light and the humidication equipment will work.
When PV ≥ SV, the green light will go out and the humidification
equipment will stop working.
1. Long press the SET button until the appears and the ashes.
2. Short press the UP or DOWN button and there will be a ashing,
then press the SET button to select the Humidity.
3. Press UP or DOWN to adjust the RUN value you required.
4. Short press SET button to set STOP temperature and next value.
5. Long press SET button to save and exit.
Set dehumidication mode:
To set the RV(RUN value) > SV(STOP value), the system will be in
dehumidication mode and the will appear on
the display. When PV(Measuring temperature) > RV, the green indicator
of HUMIDITY will light and the dehumidication equipment will work.
When PV ≤ SV, the green light will go out and the dehumidification
equipment will stop working.
1. Long press the SET button until the appears and the ashes.
2. Short press the or button and there will be a ashing, then
press the SET button to select the humidity.
3. Press or to adjust the RUN value you required.
4. Short press SET button to set STOP temperature and next value.