5
4.7 Industrial standard:
FCC Part 15 Subpart B, EN55032, Class A
IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air)
IEC61000-4-3 (RS): 10V/m (80~1000MHz)
IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port: ±2kV
IEC61000-4-5 (Surge): Power Port: ±2kV/DM, ±4kV/CM;
Data Port: ±2kV
IEC61000-4-6 (CS): 3V (10 kHz-150 kHz); 10V (150 kHz-80MHz)
IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s)
Frequency range: 150kHz-80MHz
Impact: IEC60068-2-27
Free Fall: IEC60068-2-32
Vibration: IEC60068-2-6
5. Interface Definition
5.1 10/100Base-TX Ethernet interface:
This series of switches provides MDI/MDI-X self-identification with
cable support on all 10/100Base-TX ports. In use, the Ethernet port of
the switch can be connected with other Ethernet terminal devices
through network cables (direct or cross).Please use Class 5 shielded
twisted pair. The Ethernet port pin definition is shown in the following
figure:
RJ45 port supports automatic MDI/MDI-X operation, you can use a
straight line to connect to the PC or server, connect to other switches
or hubs. In the through line (MDI), pins 1, 2, 3, 4, 5, 6, 7, 8 correspond
to the connection;