13. TROUBLESHOOTING
Be sure to observe the safety instructions during troubleshooting.
Valve leaking around
stem and gland
Damaged or worn gland packing
Refer to the "8.1 Replace the Gland
Packing" sections of this manual
Valve leaking around
bonnet
Tighten body-bonnet bolts
Refer to the "8.2 Replace the Gasket"
sections of this manual
Valve leaking around pipe
connections
T-Bolts too tight or tightened unevenly
Loosen T-Bolts, re-tighten T-Bolts evenly
If the valve has not been operated over for a
long time, may stem is stuck
Lubricate stem threads with grease
Check flow arrow direction on valve body
The arrow on the valve body must be in the
same direction of the liquid flow
Flange covers not removed
The valves and pipeline must be protected
against freezing media
Warm up pipeline system and use valve
jacket
Dirt or debris between sealing surfaces
Open valve to flush or clean sealing
surfaces
Damaged disc seat or body seat
Refer to the "8.3 Metal to Metal Sealing"
sections of this manual
Blockage in the pipeline system
Damage to the parts bearing pressure
because of water hammer
To avoid water hammer, where necessary
in the pipeline system, place water hammer
protective equipment