62
730.138 | 08.12
EN
6\VWHPVWRSSHG
GXHWR
SULRULW\WHVW
The solar circuit has stopped because
the controller is conducting a priority
test. This test checks whether, instead
of the second-priority storage tank, the
first-priority storage tank could also be
loaded.
This test can take several minutes, as the
collector array must heat up sufficiently.
6RODUFLUFXLW
UXQQLQJGXHWR
LQWHUYDOWHVW
Solar circuit is running due to interval
test.
The collector's heat transfer fluid is be-
ing transported to the sensor.
7KHUPDO
IURVWSURWHFWLRQ
LVDFWLYH
The solar circuit is running in order
to protect the collector from icing up.
9ROXPHIORZIDXOW
VRODUFLUFXLW
FKHFNK\GUDXOLFV
$LULQV\VWHP"
Despite the fact that the pump is
running, the temperature difference
between the collector and the external
heat exchanger is too great.
-> Volume flow is too low.
Check the solar circuit's hydraulics,
pump, valves, and shut-off devices.
If necessary, bleed the system, open
the shut-off devices, and flush out
blockages.
9ROXPHIORZIDXOW
VHFRQGDU\FLUFXLW
FKHFNK\GUDXOLFV
$LULQV\VWHP"
Despite the fact that the pump is
running, the temperature difference
between the external heat exchanger
and the storage tank is too great.
-> Volume flow is too low.
Check the loading circuit's hydraulics,
pump, valves, and shut-off devices.
If necessary, bleed the system, open
the shut-off devices, and flush out
blockages.
1LJKWFLUFXODWLRQ
GHWHFWHG&KHFN
QRQUHWXUQYDOYHV
DQGWKHWLPHVHW
Gravity circulation is causing the collec-
tor to be heated at night.
Check the gravity brake (non-return
valve) and the time set in the control-
ler.
&ROOHFWRU
FRQQHFWLRQVPD\
EHZURQJZD\
URXQG&KHFN
K\GUDXOLFV
Solar circuit shows "suspicious" cycle
behaviour.
Check the collector array's supply and
return pipes, and mount them cor-
rectly if applicable.
,QIRGRXEOH
DOORFDWLRQ
FRQIOLFWLQJ
VHWWLQJV
The internal settings check
has identified conflicting settings, or
double allocation of sensors.
Check the function's time settings.
Double allocation of sensors is per-
mitted, and this is only intended as
information.
3ODXVLELOLW\FKHFN
XVHUPDQXDO
3
The internal plausibility check
has identified conflicting settings.
Look up the error code in the operat-
ing instructions (chapter 12) and
check/correct the entries.
)DXOWGHWHFWHG
LQVHQVRURU
VHQVRUFDEOH
A sensor error has been detected. Locate and check the corresponding
sensor(s) in the display menu.
6HQVRUFDEOH
LQWHUUXSWHG
RUQRVHQVRU
FRQQHFWHG
Sensor cable is interrupted, incorrectly
connected, or the sensor is possibly
defective.
Check connection and/or sensor ca-
ble. Possibly check sensor and sensor
cable using an ohmmeter.