70
730.138 | 08.12
EN
13.3 Parameter values for functions
Circulation:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Time controlled:
- 00.00 23.59 Programming a time period which goes beyond
midnight (24.00) is not possible.
Temperature controlled:
Switch-on temperature:
30 °C 0 °C
Switch-off
temperature -2 K
Switch-off temperature:
35 °C
Switch-on
temperature
+2 K
95 °C
Pulse controlled:
Circulation time:
2 min 1 min 10 min
Wait time:
10 min 0 min 60 min
Back-up heating:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature:
55 °C 0 °C
Switch-off tem-
perature -2 K
Switch-off temperature:
60 °C
Switch-on
temperature
+2 K
95 °C
Time controlled:
-- 00.00 23.59 Programming a time period which goes beyond
midnight (24.00) is not possible.