71
730.138 | 08.12
EN
Solid fuel boiler:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature difference:
6 K
Switch-off
temperature
difference
+2 K
20 K
Switch-off temperature difference:
3 K 0 K
Switch-on
temperature
difference -2 K
Maximum heat target temperature:
60 °C 0 °C 150 °C
Minimum heat source temperature:
50 °C 30 °C 95 °C
Quick charge:
Factory
setting
Adjustable
down to min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature:
50 °C 0 °C 95 °C
The switch-off temperature is adjusted according
to the hysteresis.
Switch-off temperature:
52 °C
Switch-on tem-
perature +2 K
Switch-on
temperature +
10 K