EasyManua.ls Logo

DINGLI BA28RT - Page 47

DINGLI BA28RT
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
43
Class C
Item
Fault
Restriction logic
1
PVG fault
1 No restriction
2 Show corresponding faulty code.
2
chains broken switch
1 Restrict main boom extending out, showing code 51
3
engine fault
1 No restriction for operation system
2 Show corresponding faulty code.
4
tower sensor for articulate
boom fault
1 No restriction for operation system, but showing
code 95 when moving.
5
upper sensor for articulate
boom fault
1 Restrict articulate boom extending out, showing code
37.
2 The main boom only can be located between -55
55°, showing code 66.
Lower the platform by activating bypass button on ground console or platform console, and then
operating corresponding operation, when there is one fault or more belonging to class B or class
C.