EasyManua.ls Logo

DINGLI BA28RT - Machine Orientation When Doing Speed Tests

DINGLI BA28RT
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specification
14
Machine Orientation When Doing Speed Tests
Lift: Boom Retracted. Telescope Retracted. Lift Up, Record Time, Lift Down, Record Time. The
result will be different when the boom is fully extended.
Swing: Boom at lifted position. Telescope Retracted. Swing the Turntable to the end stop, Record
Time. Swing the Opposite Direction, Record Time. Telescope extended, repeat it above.
Telescope: Boom at Full Elevation; Telescope Retracted; Telescope Out, Record Time.
Telescope In, and record Time.
Drive: Test to be done on a smooth level surface. Drive Select Switch should be set at high speed
mode. Start approximately 8 m from starting point so that the unit is at maximum speed when
starting the test. Results should be recorded for a 60 m course. Drive Forward, record time. Drive
Reverses, Record Time.
Drive (Above Horizontal): Test should be done on a smooth level surface. Drive Select Switch
should be set to low speed mode. This verifies that the switches are working when the boom is
above horizontal. Results should be recorded for a 15 m. course. Drive Forward, Record Time.
Drive Reverse, Record Time.
Platform Rotate: Platform level and completely rotated one direction. Rotate the opposite
direction, Record Time. Rotate the other direction, Record Time.
Articulating Jib: Platform level and centered with the boom. Start with the Jib down. Jib Up,
Record Time. Jib Down, Record Time.
Test Notes
1 Stop watch should be started with the function, not with the controller or switch.
2 Drive test results reflect 385/45-28 tires.
3 All speed tests are run from the platform. These speeds do not reflect the ground control
operation.
4 The platform speed knob control must be turned to rapid position.
5 Function speeds may vary due to cold, thick hydraulic oil. Test should be run with the oil
temperature above 10 F (38° C).
6 Some flow control functions may not work with the speed knob clicked into the creep position.
DEUTZ TD 2.9-L4 Engine Specification
Displacement
2.925L
Number of Cylinder
4
Bore & Stoke
92×110mm
Rated Power
55.4kW/2600r/min
Maximum Torque
260N.m/1800r/min