OPERATORS MANUAL with Maintenance Information
Function Tests
23
1 Select a test area that is firm, level and
free of obstruction.
2 Be sure the battery pack is connected.
3 Turn on the main power
At the Ground Controls
4 Pull out the platform red Emergency Stop
button to the on position. Turn the ground
red Emergency Stop button clockwise to
the on position.
5 Turn the key switch to ground control.
6 Observe the display on the ground
controls.
Result: The display will come on and
display SYSTEM READY.
Test Emergency Stop
7 Push in the ground red Emergency Stop
button to the off position.
Result: No functions should operate.
8 Turn the red Emergency Stop button
clockwise to the on position.
Test Up/Down Functions and
Function Enable
A buzzer with different sound frequency is
controlled in central system. The descent
alarm sounds at 60 beeps per minute. The
descent delay alarm sounds at 180 beeps per
minute. The alarm that goes off when the
machine is not level sounds at 180 beeps per
minute. An optional automotive-style horn is
also available.
9 Do not press the lift function enable button.
Press and hold the platform up/down
button.
Result: No function should operate.
10 Press and hold the lift function enable
button. Press and hold the platform up
button.
Result: The platform should rise.
11 Press and hold the lift function enable
button. Press and hold the platform down
button.
Result: The platform should lower the
descent alarm should sound while the
platform is lowering. The platform stop at
the height is approximately 3.5 m from the
ground. The descent delay alarm will
sound.
Note: Be sure the area below the platform is
clear of personnel and obstructions before
continuing.
12 Press and hold the lift function enable
button. Press and hold the platform down
button.
Result: The platform should lower to end.
The descent delay alarm should sound
while the platform is lowering.
Test the Emergency Lowering
13 Activate the up function and raise the
platform approximately 60 cm.
14 Push in the red Emergency Stop button to
the off position.
15 Turn the ground red Emergency Stop
button clockwise to the on position.
16 Press and hold the emergency lowering
down enable button. Press and hold the
emergency lowering down button.
Result: The platform should lower.
17 Turn the key switch to platform control.
At the Platform Controls
Test Emergency Stop
18 Push in the platform red Emergency Stop
button to the off position.
Result: No functions should operate.