OPERATOR’S MANUAL with Maintenance Information
Function Tests
28
than 3 m from the ground, the outriggers
will not lower.
56 Lower the platform to the end.
57 Push and hold the auto level button.
58 Press and hold the function enable switch.
Activate the proportional control handle in
the direction indicated by the yellow arrow.
The outriggers will extend and level the
machine. A beep will sound when the
machine is level.
59 Raise the platform.
⊙ Result: The platform should rise to full
height.
60 Lower the platform.
Test Auxiliary Lowering
61 Push and hold the function enable switch
and raise the platform approximately 60
cm.
62 Push in the red Emergency Stop button to
shut off the engine.
63 Pull out the red Emergency Stop button to
the on position.
64 Push and hold the function enable switch.
Activate the control handle in the direction
indicated by the yellow arrow.
⊙ Result: The platform should lower.
Test Outrigger Auxiliary Retract
65 Lower the platform to the lowest position.
66 Operator comes back to the ground, and
operates the machine on the ground
control.
67 Press and hold the lift function enable
button. Press and hold the platform down
button. Press and hold the overload
indicator button
⊙ Result: The outrigger should retract.