OPERATOR’S MANUAL with Maintenance Information
Maintenance
64
Display
for
Platform
Display for Ground Description Repair
82 82 Left Rear Otrg Coil Flt
Power FET, channel LEFT
REAR OUTRIGGER fails
check the wiring,
replace the valve
83 83 Right Front Otrg Coil Flt
Power FET, channel RIGHT
FRONT OUTRIGGER fails
check the wiring,
replace the valve
84 84 Right Rear Otrg Coil Flt
Power FET, channel RIGHT
REAR OUTRIGGER fails
check the wiring,
replace the valve
85 85 Outrigger Ext Coil Fit
Power FET, channel EXTEND
OUTRIGGER fails
check the wiring,
replace the valve
86 86 Outrigger Ret Coil Fit
Power FET, channel RETRACT
OUTRIGGER fails
check the wiring,
replace the valve
95 95 Machine Type Fauit Wrong Machine Type Selected
Reinstall Machine
Type
OL 98 Platform Overload Platform Overload Fault
Remove the excess
load immediately.
LL
Machine Tilted Beyond Safe
Limits Fault
check the wiring,
replace the sensor
For more information, please consult the appropriate Dingli Service Dept.