VII. Using the Generator
1Service environment of the generator
Applicable temperature: -5 ~ 40°C;
Applicable humidity: below 95%;
Applicable altitude: regions below 1,500 m (It shall be used by
reducing power in regions above 1,000 m).
Standard atmospheric condition
Ambient temperature Tr: 298k (25°C)
Relative air humidity Фr: 30%
Absolute atmospheric pressure Pr: 100kPa
When actual environmental condition is inconsistent with the condition
of output power of the generator set:
Every 5°C of increase in ambient temperature will reduce the power
of generator by about 2%
Every 30% of increase in relative humidity of air will reduce the power
of generator by about 1.5%
Every 300 m rising of ASL will reduce the power the generator by
about 4.5%
2Generator wiring
When the generator is connected to household power source as a
backup power supply, the connection shall be carried out by a
professional electrician or a person familiar with electricity.
After connecting the load to the generator, check carefully wh ether
electrical connection is safe and reliable. Improper electrical
connection may cause generator damage, burning or fire.
Avoid connecting this generator to commercial power outlet.
When extending the cable, be sure not to exceed its length.
60m cross-section area is 1.5mm²
100m cross-section area is 2.5mm²