Start Up
6.
If you suspect the spray tip or hose
is clogged or that pressure has not
been fully relieved:
a.
VERY SLOWLY loosen the tip
guard retaining nut or the hose
end coupling to relieve pressure
gradually.
c.
Clear airless hose or spray tip
Flush Storage Fluid
This sprayer arrives from the factory with a
small amount of test material in the system.
It is important that you flush this
material from the sprayer before using it
for the first time. See Cleaning Fluid
Compatibility, page 20 and Static
Grounding Instructions (Oil-Based
materials), page20for additional
information when using oil-based materials.
1.
Perform Pressure Relief
2.
Make certain ON/OFF switch is OFF.
3.
Separate drain tube (smaller) from
4.
Place drain tube in a waste pail.
5.
Submerge suction tube in a pail par-
tially filled with water or flushing fluid.
If spraying oil-based materials, sub-
merge the suction tube in mineral
spir- its, or compatible cleaning
solvent. If spraying water-based
materials, sub- merge the suction
tube in water.
7.
Plug power supply cord into a
properly grounded electrical outlet.
8.
Align setting indicator with
Prime/Clean setting on pressure
9.
Turn ON/OFF switch to ON position.