2
2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
UNIT
Heating Power Input
Running Current
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Ship Dimensions(L/W/H)
Net Weight
Shipping Weight
KW
A
W
RPM
dB(A)
inch
gal/min
kPa
mm
mm
kg
kg
See the drawing of the units
See package lable
see nameplate
see package label
PASRW030
2.2
10.5
1
rotary
1
150
850
horizontal
54
1.5
30
10
PASRW040
3.2
15.5
1
scroll
1
180
850
horizontal
56
1.5
30
10
208-230V~/60Hz
PASRW045
3.6
17.5
1
scroll
1
180
850
horizontal
56
1.5
36
10
Heating: Ambient temp (DB/WB): 80ºF (26.7ºC) / 75.8ºF (24.3ºC)
Water temp (in/out): 80ºF (26.7ºC) / 92ºF (28ºC)
*** REFRIGERANT : R410A
Visit www.ahridirectory.org for full Distinction Heat Pump Performance Data