FM25/FM25X Operators Manual Prepare - 33
Inspect Jobsite
Inspect Jobsite
Follow U.S. Department of Labor regulations on excavating and trenching (Part 1926, Subpart P) and
other similar regulations.
Mark proposed path with white paint and have underground utilities located before working.
– In the US or Canada, call 811 (US) or 888-258-0808 (US and Canada). Also contact any local utilities
that do not participate in the One-Call service.
– In countries that do not have a One-Call service, contact all local utility companies to have
underground utilities located.
Inspect jobsite and perimeter for evidence of underground hazards, such as:
– “Buried utility” notices
– Utility facilities without overhead lines
– Gas or water meters
– Junction boxes
– Drop boxes
– Light poles
– Manhole covers
– Sunken ground
Mark location of all buried utilities and obstructions.
Prepare Jobsite
Jobsite hazards could cause death or serious injury. Use
correct equipment and work methods. Use and maintain proper safety
equipment.
274-050; 274-724 (2P)
To help avoid injury:
Classify jobsite as electric if jobsite classification is in question or if the possibility of unmarked
electric utilities exists.
Expose lines by hand before digging. Cutting high voltage cable can cause electrocution.
Remove all vegetation near operator’s station. Contact with trees, shrubs, or weeds during electrical
strike could result in electrocution.