Set-up subject to change without notice. For packages not listed contact Dixie-Narco Factory
Service at (800) 688-9090. Page 72 of 72
SYMPTOM: PRODUCT HOT
Possible Cause: Compressor Starts But Will Not Keep Running
WHAT TO CHECK SOLUTION
1. Is the temperature control pointer set on its highest setting?
YES
1. NO, adjust the pointer to a higher setting.
2. Domestically, is the voltage supply within +/- 10% of rating on
serial plate?
YES
2. NO, consult the power company.
3. Is the condenser clear of obstruction?
YES
3. NO, clear or clean..
4. Is the condenser fan blade turning?
YES
4. NO, free the obstruction or replace the blade if
needed.
5. Is the condenser fan motor operational?
YES
5. NO, replace.
6. Is the temperature control operational?
YES
6. NO, replace
7. Is the tube from the compressor to the condenser free of kinks?
YES
7. NO, repair or replace
8. Is the capillary tube free of kinks?
YES
8. NO, replace.
9. Is the thermal overload operational?
YES
9. NO, replace.
10. Is the start relay operational?
YES
10. NO, replace.
11. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number available.
SYMPTOM: PRODUCT HOT
Possible Cause: Miscellaneous
WHAT TO CHECK SOLUTION
1. Is the evaporator fan motor working?
YES
1. NO, replace motor.
2. Has the refrigeration system lost its charge?
NO
2. YES, replace the refrigeration system.
3. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number available.