8 Button C2
When you are planning a eld, it adds a waypoint. When planning a eld, the function cannot be
customized. When you are not planning a eld, then the default function is Delete Route. Use the
app to customize the button.
The table below is a summary for how to control the spraying system via the remote controller in
different modes.
Mode
Spray
Rate Dial
Spray
Button
Pause
Switch
Button A Button B
Aircraft
Control
Switch Dial
Button C1 Button C2
Route
operation
mode
/ / Pause Customizable Customizable
Switch
between
aircraft
Customizable Customizable
A-B Route
operation
mode
/ / Pause Customizable Customizable / Customizable Customizable
Manual
operation
mode
Adjust
spray rate
Start
or stop
spraying
/ Customizable Customizable / Customizable Customizable
Manual Plus
operation
mode
Adjust
maximum
spray rate
/ / Customizable Customizable / Customizable Customizable
Field Plan / / / / / /
Start or end
obstacle
measurement
Add a waypoint
RTH Button
Press and hold the RTH button to bring the aircraft back to the last recorded Home Point. The LED
around the RTH Button will blink white during RTH procedure. Users can control aircraft heading
while it ies to the Home Point. Press this button again to cancel RTH and regain control of the
aircraft.