Page 11 of 14
9 Specification
Voltage: 220 – 240Va.c. 50Hz
Wattage: 75W
Top Tank: 2.2 Litre Capacity
Lower Tank: 2.2 Litre Capacity (with top tank fitted)
Chiller Tank: 600ml
10 Troubleshooting
10.1 Water will not flow through Tap/s
If the Upper and Lower water tanks are full of water and the Chilled
Water tap is not dispensing any water when pressed down, there is
probably an air bubble preventing the water flowing down. This can be
easily rectified by following the steps below:
Remove the Upper and Lower water tanks from the top of the unit. (Take
care as water will drain out the bottom of the water tanks). There will be a
small amount of water in the round receptacle on top of the main unit.
Place a cup under the Chilled Water button tap.
Press down on the Chilled Water button and continue to hold it down.
The remaining water in the receptacle should then drain down into the
chiller tank.