RMD10 Troubleshooting
41
E50 Gas lock after 3 ignition
attempts
Error Ignition not possible.
The gas cylinder is empty.
Replace the gas cylinder.
Reset the error manually.
E51 Gas lock, internal error in
the power module
Error Reset the error manually.
Contact customer service if
this error occurs again.
E52 Ground contact, gas
valve
Error Reset the error manually.
Contact customer service if
this error occurs again.
In autonomous gas
operation:
The battery charge of the
battery packs is low.
Error Insert new batteries.
E53 Ground contact ignition
electrode
Error Reset the error manually.
Contact customer service if
this error occurs again.
Tank stop mode: Gas
operation is blocked for
15 minutes.
Warning Wait 15 minutes or switch
to another operating
mode.
Door left open Warning Close the door.
Recurring beep
Code LEDs Fault Typ e Solution
50'2:(67ERRN6HLWH'RQQHUVWDJ0DL

Other manuals for Dometic 10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic 10 Series and is the answer not in the manual?

Dometic 10 Series Specifications

General IconGeneral
TypeAbsorption
Energy Source12V DC, 230V AC, Gas
FeaturesLED lighting
Climate ClassT (Tropical)
DoorSingle door, left or right hinged (model dependent)

Related product manuals