Troubleshooting RMD10
40
E07 No cooling capacity in
gas mode
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
E08 No cooling power in AC
operation
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
E09 No cooling power in DC
mode
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
W10 Beep Door is open for more
than 2 minutes; a signal
tone is emitted.
Warning Close the door.
W11 DC overvoltage (> 16 V). Warning Reduce DC supply voltage.
E12 Gas valve check error Error Gas operation is not
possible.
Reset the error manually.
Contact customer service if
this error occurs again.
E13 Internal communication
error
Error Gas operation not
possible.
Reset the refrigerator.
Reset the error manually.
Contact customer service if
this error occurs again.
Code LEDs Fault Typ e Solution
50'2:(67ERRN6HLWH'RQQHUVWDJ0DL

Other manuals for Dometic 10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic 10 Series and is the answer not in the manual?

Dometic 10 Series Specifications

General IconGeneral
TypeAbsorption
Energy Source12V DC, 230V AC, Gas
FeaturesLED lighting
Climate ClassT (Tropical)
DoorSingle door, left or right hinged (model dependent)

Related product manuals