CLIMATE CONTROL
AIR CONDITIONERS
Form No. 3317817.000 1/21 | ©2021 Dometic Corporation
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
Brisk Air (457915, 459516), Brisk II (B57915, B59516),
High Performance (540315, 540316), Blizzard NXT (H540315, H540316),
Penguin (640312, 640315, 640316), Penguin II (640312C, 640315C, 640316C),
FreshJet (FJX3473, FJX3573)
EN
Value Air Distribution Box,
Mechanical
Installation and Operation Manual . ........2

Other manuals for Dometic 457915

Questions and Answers

  • D
    Diana WatsonAug 17, 2025
    Why is my Dometic 457915 Air Conditioner not maintaining the desired temperature?
    • J
      Jillian BrownAug 17, 2025
      Your Dometic Air Conditioner might struggle to maintain the desired temperature if the RV is gaining heat due to high outdoor temperatures or humidity. To mitigate this, park the RV in a shaded area. Additionally, use window shades, blinds, or curtains, keep windows and doors closed or minimize their use, and avoid using heat-producing appliances inside the RV. You can also operate the product in the High Fan/Cooling mode or start the product before the outside temperature increases.
  • D
    Debra RoweAug 20, 2025
    How to fix a Dometic Air Conditioner that won't turn on?
    • J
      John FitzgeraldAug 20, 2025
      If your Dometic Air Conditioner isn't working, check if the circuit breaker has been activated and reset it if necessary. Also, inspect the fuse and replace it if it has blown.
  • K
    Kurt ChambersAug 22, 2025
    What to do if my Dometic 457915 Air Conditioner doesn't cool enough?
    • W
      William YoungAug 22, 2025
      If your Dometic Air Conditioner isn't maintaining the desired temperature, consider that the RV's heat gain could be affected by high outdoor temperatures or humidity. Try parking the RV in a shaded area. Additionally, use window shades, blinds, or curtains, keep windows and doors closed or minimize their use, and avoid using heat-producing appliances inside the RV. You can also operate the product in the Turbo Fan/Cooling mode or start the product before the outside temperature increases.
  • K
    Kyle AllenAug 25, 2025
    What to do if frost forms on the evaporator coil of my Dometic 457915?
    • P
      Paul SuarezAug 26, 2025
      If you notice frost forming on the evaporator coil of your Dometic Air Conditioner, it could be due to very cold output at a very low air speed, or the outside temperature may be relatively low. First, inspect and clean the filter. Then, open the air vents and remove any obstructions. Confirm that a minimum of two distribution vents, or the quick cool vent and one vent, are open. Adjust the thermostat control knob to a warmer setting (counterclockwise). You can also operate the product on any Fan Only setting until the coil is free of frost.
  • D
    danielsbrentAug 27, 2025
    How to prevent condensation forming on ceilings from Dometic 457915?
    • J
      jonespaulAug 28, 2025
      To reduce condensation forming on ceilings, windows, or other surfaces when using your Dometic Air Conditioner, keep doors and windows closed when the unit is in operation. This minimizes the amount of water vapor in the air that can condense on cooler surfaces.
  • W
    William LeeAug 30, 2025
    What to do if Dometic 457915 Air Conditioner is not working when connected to land line?
    • K
      Kristie BrownAug 30, 2025
      If your Dometic Air Conditioner isn't working or is operating poorly when connected to a land line, first confirm that the land line is plugged into the power supply and that it is properly-sized for the product's power load.
  • M
    Melissa CaldwellSep 1, 2025
    What to do if Dometic 457915 Air Conditioner is not working when connected to generator?
    • H
      Henry StevensonSep 2, 2025
      If your Dometic Air Conditioner is not working, or working poorly, when connected to the motor generator, you should confirm the motor generator is running and producing power. Also, confirm the fuse or circuit breaker is open, ensuring the fuse is not blown, or the circuit breaker is on and not activated.
  • D
    Debra RichardsonSep 4, 2025
    What to do if my Dometic Air Conditioner does not operate?
    • C
      Cynthia RomanSep 4, 2025
      If your Dometic Air Conditioner isn't working, the circuit breaker may have activated. Try setting or resetting the circuit breaker. Alternatively, a fuse may have blown, in which case you should replace the fuse.
  • E
    Emily Boone MDSep 6, 2025
    What to do if my Dometic 457915 does not operate well when connected to a land line?
    • R
      Rebecca SheltonSep 7, 2025
      If your Dometic Air Conditioner isn't operating well when connected to a power supply by a land line, first confirm the land line is plugged into the power supply. Also, confirm the land line is properly-sized for the product’s power load.
  • L
    Latasha HarmonSep 9, 2025
    What to do if my Dometic Air Conditioner does not operate when connected to the motor generator?
    • J
      Joanna RichardsSep 9, 2025
      If your Dometic Air Conditioner is not working properly when the RV is connected to the motor generator, confirm the motor generator is running and producing power.

Summary

Explanation of Symbols and Safety Instructions

Recognize Safety Information

Explains the safety alert symbol and its meaning for potential injury hazards.

Understand Signal Words

Explains signal words (DANGER, WARNING, CAUTION) indicating hazard levels.

Supplemental Directives

Provides directives to reduce risks before installation, operation, or service.

General Safety Messages

Lists general safety warnings related to electrical shock, fire, and explosion hazards.

Intended Use

General Information

Tools and Materials

Lists recommended tools and materials for installation.

Model Identification

Explains where to find model and serial number labels on the unit.

ADB Components

Identifies the main components of the ADB with a diagram.

Rooftop Component Dimensions by Model

Freshjet

Provides dimensions and clearance for the Freshjet model.

Brisk Air

Provides dimensions and clearance for the Brisk Air model.

Brisk II

Provides dimensions and clearance for the Brisk II model.

Blizzard NXT

Provides dimensions and clearance for the Blizzard NXT model.

High Performance

Provides dimensions and clearance for the High Performance model.

Penguin

Provides dimensions and clearance for the Penguin model.

Penguin II

Provides dimensions and clearance for the Penguin II model.

ADB Component Dimensions

Placement Requirements

Tilt Requirements

Outlines tilt allowances for rooftop component installation.

Specifications

Wiring Diagrams

Pre-Installation

Determining Your Cooling Needs

Guides users in assessing cooling requirements for the RV.

Preparing the RV Roof Opening

Explains how to prepare the roof opening for unit installation.

Using an Existing Roof Vent Opening

Details the process of preparing the roof when an existing vent is present.

Making a New Roof Opening

Describes how to create a new roof opening for installation.

Routing the Wiring

Provides instructions on how to route electrical wiring for the rooftop component.

Positioning the Rooftop Component

Guides on how to place the rooftop unit onto the prepared roof opening.

Preparing to Work Inside the RV

Installation

Installing the Foam Dividers

Explains how to install foam dividers to fill gaps based on roof thickness.

Roof Thickness 1.25 to 5.5 in.

Details foam divider selection for roof thicknesses from 1.25 to 5.5 inches.

Roof Thickness 6.0 - 7.5 in.

Details foam divider selection for roof thicknesses from 6.0 to 7.5 inches.

Securing the Unit

Wiring the Unit to the Power Supply

Connecting the Power Supply

Finalizing the Installation

Operation

Understanding the Controls

Explains the function of the temperature and fan control knobs.

Understanding the Settings

Details various operational settings for the unit.

Maintenance

Cleaning the Air Filter

Provides instructions for cleaning the air filter.

Cleaning the ADB Housing

Explains how to clean the ADB housing and control panel.

Troubleshooting

Disposal

LIMITED TWO-YEAR WARRANTY

Overview

This document describes the Dometic Value Air Distribution Box (ADB), Mechanical, which is a component of Dometic Climate Control Air Conditioners designed for Recreational Vehicles (RVs).

Function Description:

The Value Air Distribution Box (ADB), Mechanical, is an internal component of an RV air conditioner (AC) system. It works in conjunction with a rooftop component to provide climate control within the RV. The ADB is responsible for distributing conditioned air, housing the control mechanisms, and containing the air filter. It is designed for installation on the roof of an RV, either during manufacturing or as an aftermarket addition. The system is comprised of two main parts: the rooftop component (which includes the compressor, condenser, and evaporator coils) and the internal ADB component (which includes controls, air distribution, and filtration). The manual emphasizes proper installation to ensure a functional and safe product.

Important Technical Specifications:

The manual provides detailed electrical specifications for various models of Dometic air conditioners that use this ADB. Key specifications include:

  • Nominal Capacity Cooling (BTU HR): Ranges from 11,000 to 15,000 BTU HR, depending on the model.
  • Electrical Rating: All models operate on 115 VAC, 60 Hz, 1 phase.
  • Compressor Amps (Rated Load/Locked Rotor): Varies by model, with rated loads typically between 10.5 A and 13.6 A, and locked rotor amps between 52.0 A and 73.0 A.
  • Fan Motor Amps (Rated Load/Locked Rotor): Varies by model, with rated loads typically between 2.0 A and 3.5 A, and locked rotor amps between 5.6 A and 10.0 A.
  • Refrigerant (R-410A): Quantity ranges from 12.7 oz to 29.5 oz, depending on the model.
  • Minimum Wire Size: 12 AWG for copper wiring up to 24 ft (7.3 m). For longer wire lengths, consult the National Electrical Code.
  • AC Circuit Protection (Installer Supplied): Requires a 20 Amp time delay fuse or circuit breaker.
  • Minimum Generator Size:
    • For 1 unit: 3.5 kW
    • For 2 units: 5.0 kW
    • (Note: These are general guidelines; total RV power usage and altitude/maintenance factors should be considered.)

Rooftop Component Dimensions (by Model):

The manual includes detailed diagrams and measurements for various rooftop components, including Freshjet, Brisk Air, Brisk II, Blizzard NXT, High Performance, Penguin, and Penguin II. These dimensions include height, width, length, and clearance requirements (e.g., 18.0 in. (457 mm) clearance for Brisk Air, 4.0 in. (102 mm) clearance for Blizzard NXT).

ADB Component Dimensions:

Internal dimensions of the ADB component are also provided, including front of unit, width, length, and roof opening dimensions.

Placement Requirements:

  • Roof Opening: Requires a 14.3 in. x 14.3 in. (363 mm x 363 mm) square opening (±0.1 in. (3 mm)).
  • Rafter/Joist Support: Frames must be spaced no greater than 16.0 in. (406 mm) on center.
  • Roof to Ceiling Distance: Must be between 1.5 in. (38 mm) and 6.0 in. (152 mm).
  • Location: For a single unit, slightly forward of the RV's center (front to back) and centered side to side. For two units, at 1/3 and 2/3 the length of the RV, centered side to side.
  • Tilt Allowance: Maximum acceptable roof tilt varies by model: 15° for Brisk Air, Brisk II, High Performance, Blizzard NXT, and FreshJet models; 8° for Penguin and Penguin II models. Measurements should be taken on a level surface.

Usage Features:

  • Controls: The ADB features a Temperature Control Knob (7 positions) and a Fan Control Knob (7 positions, including OFF).
  • Temperature Control: Manages ON/OFF operation within a temperature range of approximately 65–90 °F (18–32 °C) at the ADB inlet.
  • Fan Control:
    • Fan-Only Speeds (3 Steel Gray Positions): Low Fan (one dot), High Fan (two dots), Turbo Fan (three dots) for air circulation without cooling.
    • Cooling Fan Speeds (3 Dark Gray Positions): Cool Low Fan (one dot), Cool High Fan (two dots), Cool Turbo Fan (three dots) for air circulation while cooling.
  • Cooling Operation: Selectable coolness levels: Low Cool (shorter dash for nighttime), High Cool (medium dash for normal cooling), and Turbo Cool (longest dash for maximum cooling and dehumidification). The compressor cycles on/off to maintain the selected temperature.
  • Safety: The manual emphasizes safety warnings regarding electrical shock, fire, explosion, and lifting hazards. It also advises against improper installation or modification and recommends service by qualified personnel.

Maintenance Features:

  • Air Filter Cleaning: The return air filter should be removed periodically (at least every two weeks of operation), washed with soap and warm water, and dried completely before reinstallation. Running the unit without the filter can degrade performance.
  • ADB Housing Cleaning: The ADB housing and control panel should be cleaned with a soft cloth dampened with a mild detergent. Furniture polish or scouring powders should not be used.
  • Blower Motor: Factory-lubricated and requires no service.

Troubleshooting:

The manual includes a troubleshooting table for common issues such as the product not operating (due to circuit breaker, fuse, or power supply issues), or frost forming on the evaporator coil (due to low air speed or low outside temperature). Suggested remedies include resetting breakers, replacing fuses, confirming power supply, inspecting/cleaning filters, opening air vents, and adjusting the thermostat.

Warranty:

A limited two-year warranty is available at www.dometic.com/warranty.