3
CCC Ducted Installation Instructions
MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUM
NO. CAPACITY RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STATIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR
(BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE**
COOLING AMPS AMPS “ W. C. SUPPLIED 1 UNIT/ 2 UNITS
57908.321 7,180 6.9 36.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 75 2.5 KW / 4.0 KW
57908.521 7,100 6.6 34.0 2.5 5.8 325 / 250 0.55 / 0.90 17.0 20 Amp 75 2.5 KW / 4.0 KW
57912.321 11,000 9.5 53.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 94 2.5 KW / 4.0 KW
57912.531 11,000 8.0 53.0 2.5 5.8 325 / 250 0.55 / 0.90 18.5 20 Amp 94 2.5 KW / 4.0 KW
57912.532 11,000 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57912.621 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 2.5 KW / 4.0 KW
57912.622 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW
57912.631 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW
57915.321 13,500 12.1 60.0 2.5 5.8 325 / 250 0.55 / 0.90 15.0 20 Amp 104 3.5 KW / 5.0 KW
57915.322 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 104 3.5 KW / 5.0 KW
57915.331 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 100 3.5 KW / 5.0 KW
57915.336 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 104 3.5 KW / 5.0 KW
57915.421 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 13.5 20 Amp 100 3.5 KW / 5.0 KW
57915.422 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 14.5 20 Amp 100 3.5 KW / 5.0 KW
57915.521 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.522 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.531 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.536 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.541 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.546 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.621 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.622 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.626 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.631 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.731 13,500 11.3 56.0 2.5 5.8 325 / 250 0.55 / 0.90 15.0 20 Amp 94 3.5 KW / 5.0 KW
57915.741 13,500 12.0 58.0 2.5 5.8 325 / 0.55 / 0.90 15.5 20 Amp 94 3.5 KW / 5.0 KW
59016.521 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 /1.1 0 26.5 20 Amp 101 3.5 KW / 5.0 KW
59016.526 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 104 3.5 KW / 5.0 KW
59016.531 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 104 3.5 KW / 5.0 KW
59016.621 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 101 3.5 KW / 5.0 KW
59136.321 15,000 12.7 60.0 2.5 6.0 325 / 250 0.40 / 1.10 34.0 20 Amp 102 3.5 KW / 5.0 KW
59136.331 15,000 12.7 60.0 2.5 6.0 325 / 250 .040 / 1.10 34.0 20 Amp 102 3.5 KW / 5.0 KW
SPECIFICATIONS
115 VAC,
60 HZ., 1PH.
12 AWG
Copper
up to 24’
* For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual appli
cations When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high
altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.