MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUM
NO. CAPACITY RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STATIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR
(BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE**
COOLING AMPS AMPS “ W. C. SUPPLIED 1 UNIT/ 2 UNITS
630035.321 13,500 12.4 60.0 3.1 8.8 335 / 250 0.12 / 0.65 24.5 20 Amp 101 3.5 KW / 5.0 KW
630035.421 13.500 11.0 50.0 3.1 8.8 335 / 250 0.12 / 0.65 19.5 20 Amp 102 3.5 KW / 5.0 KW
520300.501 N/A 7.8 49.0 3.0 8.5 375 / 275 0.55 / 1.10 20.0 15 Amp 89 2.5 KW / 4.0 KW
520310.501 9,000 7.8 49.0 3.0 8.5 375 / 275 0.55 / 1.10 20.0 20 Amp 89 2.5 KW / 4.0 KW
520315.501 13,500 10.3 62.0 3.0 8.5 375 / 275 0.55 / 1.10 16.5 20 Amp 91 3.5 KW / 5.0 KW
520315.506 13,500 10.3 62.0 3.0 8.5 375 / 275 0.55 / 1.10 16.5 20 Amp 91 3.5 KW / 5.0 KW
520316.501 15,000 13.2 79.0 2.8 7.6 375 / 275 0.70 / 1.10 30.0 20 Amp 105 3.5 KW / 5.0 KW
520316.506 15,000 13.2 79.0 2.8 7.6 375 / 275 0.70 / 1.10 30.0 20 Amp 105 3.5 KW / 5.0 KW
530515.501 13,500 10.3 62.0 3.0 8.5 375 / 275 0.55 / 1.10 17.5 20 Amp 92 3.5 KW / 5.0 KW
530515.506 13,500 10.3 62.0 3.0 8.5 375 / 275 0.55 / 1.10 17.5 20 Amp 92 3.5 KW / 5.0 KW
530516.501 15,000 13.2 79.0 2.8 7.6 375 / 275 0.70 / 0.90 29.5 20 Amp 106 3.5 KW / 5.0 KW
530516.506 15,000 13.2 79.0 2.8 7.6 375 / 275 0.70 / 0.90 29.5 20 Amp 106 3.5 KW / 5.0 KW
SPECIFICATIONS
115 VAC,
60 HZ., 1PH.
12 AWG
Copper
up to 24’
* For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These come from experiences people have had in actual applications
When sizing the generator, the total power usage of your recreational vehicle must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.