4.6.2 Gas operation (Liquid gas)
Fig. 13
Fig. 12
3. Then, press knob (3) of battery igniter
down and keep it depressed. The ignition
process is activated automatically.
4. Once the flame ignites, the pointer of galva-
nometer (4) begins moving into the green
range. The refrigerator is operational. Keep
knob (2) depressed for approx. 15 seconds
and finally release it.
1. Turn the rotary selector switch (1) to
position .
2. Turn the temperature selector (2) clockwise
and push. Keep the controller button
depressed.
Fig. 14
16
4.6.1 Electrical operation
Appliances with battery igniter
(manual energy selection)
Fig. 10
Fig. 11
Switch on the appliance by turning the energy
selection switch (1) clockwise to position :
12V operation.
230V operation,
Refrigerator operation
1 1
2
1
4.6 RM 8xx0 models
4.6.3 Setting of cooling compartment
temperature
Select the desired cooling compartment tem-
perature by turning the rotary knob (2) .
The scale starts with MIN position (small bar =
highest temperature) and climbs up to MAX
position (large bar = lowest temperature).
Note: The temperature levels do not relate to
absolute temperature values.
12V: The refrigerator operates without thermo-
static control (continuous operation).
Fig. 15
2
medium setting
3
2
4