12 Troubleshooting
Once per year Check the profile seals:
Check the seal between the roof air conditioner and the roof of
the vehicle for cracks and other damage.
Once per year Have the heat exchanger serviced:
Have the heat exchanger of the roof air conditioner serviced
by specialist workshop.
Once per year Replace the carbon filter:
Manually take off the filter cover (fig. 0, page 6).
Remove the filter (fig. a 1, page 3).
Remove the carbon filter (fig. a 2, page 7).
Put a new carbon filter in.
Clean the filter with a detergent solution and let it dry.
Put the dry filter back in.
Put the cover back on.
Problem Cause Remedy
No cooling
capacity
The roof air conditioner is not set to
cooling.
Set the roof air conditioner to
cooling.
The ambient temperature is above
50 °C.
The roof air conditioner is only
designed for ambient tempera-
tures of up to 50 °C.
The temperature set is higher that the
room temperature.
Select a lower temperature.
The ambient temperature is below
16 °C.
The roof air conditioner is only
designed for ambient tempera-
tures above 16 °C.
One of the temperature sensors is
defective.
Contact an authorised work-
shop.
The vaporiser fan is damaged.
The compressor is defective.
The heat exchange battery is pollu-
ted.
The condenser fan is damaged.
Interval Inspection/maintenance