20
users ‘ instructions
GB
B3000 PLUS
SOLUTION
temperature less than 18°C
temperature over 40°C
check the set point temperature
defective thermal protection
switch wrongly positioned
defective heating resistance
refrigerant gas is not enough
damaged compressor
thermal exchange batteries are dirty
defective internal fan
air lter is clogged
defective external fan
water outlet holes are clogged
damaged sealing gasket
no power supply
low power supply (less than 200V)
defective capacitor
defective thermal protection
CAUSA
the air conditioner does not cool suf ciently
the air conditioner does not heat enough
no air circulation into the vehicle
water leaks into the vehicle
the air conditioner does not start
the air conditioner stops running
Operations to be carried
out by the user
Operations to be carried out
by authorised personnel
3.1. Troubles, causes, solutions
3.2. Extraordinary maintenance
For the best performance of your air conditioner, have your dea-
ler/workshop clean it thoroughly before use:
thermal exchange batteries
water outlet holes are properly cleaned.
1.
2.
3 Troubleshooting, maintenance, recycling