INSTALLATION INSTRUCTIONS
FIG. 11
Electrical
Cord
Measure Ceiling
Thickness
5. Duct Divider Installation
a. Measure the ceiling thickness. See (FIG. 11).
b. Cut away the number of rows as indicated in
table below. See (FIG. 12).
Ceiling
Thickness
# Of
Rows
To Cut
Ceiling
Thickness
# Of
Rows
To Cut
Min. Max. Min. Max.
6.0 6.5 0 3.5 4.0 5
5.5 6.0 1 3.0 3.5 6
5.0 5.5 2 2.5 3.0 7
4.5 5.0 3 2.0 2.5 8
4.0 4.5 4 1.5 2.0 9
FIG. 12
Remove Rows
Starting Here
c. Carefully install the duct divider in the roof
opening 5-5/8″ from back of roof opening.
See (FIG. 13).
Foil back faces rear of unit.
FIG. 13
Rear
Base Pan
5-5/8 From Back
Of Roof Opening
Duct Divider
Front
Black Side
To Front
6. Ceiling Template Installation
a. Plug the 6 pin electrical cord from the top unit
into the matching 6 pin connector in the elec-
tronic control box. The plug is polarized and
will only t in one direction. See (FIG. 14).
FIG. 14
120 Vac
Power Supply
Cable
Connector
Unit Electrical
Cord
Proper Orientation
Of Cable Connector
b. Install supplied non metallic cable connector
in junction box hole cutout. See (FIG. 14) for
proper orientation.
c. Route the previously run 120 Vac power sup-
ply wire through cable connector and into
junction box.
d. Secure 120 Vac power supply by tightening
cable connector clamp making sure not to
damage wires. See (FIG. 14).
e. Hold the ceiling template up to the roof open-
ing and line up the channel in the ceiling
template with the previously installed duct
divider. See (FIG. 15).
FIG. 15
Duct Divider
Channel