Technical data MT 5000iQ
EN
16
14 Technical data
14.1 System
14.2 Battery monitor
14.3 Shunt
MT 5000iQ
System voltage 12 or 24 V g
Operating voltage range 8 - 32 V g
Current consumption 4 - 60 mA
Humidity 95% RF, non-condensing
Protection class III
MT 5000iQ
Technology LCD with specific segments.
Display size (L × H), in mm 49 × 28
Lighting White LED
Digital clock format HH:MM (24h)
Calendar function Automatic leap year correction
Power reserve after voltage loss 15 minutes
Dimensions (L × H × W), in mm 80 × 85 × 24
Installation cut-out, in mm 66 × 72
Weight Appr. 55 g
Smart shunt
100A
Smart shunt
200A
Smart shunt
400A
Rated current 100 A 200 A 400 A
Continuous current 120 A 240 A 480 A
Maximum current for 15 minutes 150 A 300 A 600 A
Maximum current for 7 minutes 200 A 400 A 800 A
Maximum short-term current 450 A 900 A 1800 A
Power reserve after voltage loss 15 minutes