E3 Shorted Indoor Temperature Sensor.
All heat, cool, and dehumidify opera-
tion will be locked out. Manual fan op-
eration can continue.
E4 Open circuit or out of range Outdoor
Temperature Sensor (Select Models).
Heat pump and dehumidication op-
eration will be locked out. Air condi-
tioner, furnace, heat strip, and fan op-
eration can continue to operate.
E5 Open circuit or out of range Freeze
Sensor (Select Models). Air condition-
er and dehumidication operation will
be locked out. Heat pump, furnace,
heat strip, and fan operation can con-
tinue to operate but displays the last
temperature set-point.
E6 Open circuit Humidity Sensor (Select
Models). Air conditioner and dehu-
midication operation will be locked
out. Heat pump, furnace, heat strip,
and fan can continue to operate.
E7 Loss of 120 VAC power to all power
module boards on the system. The
system will shut down.
E8 Invalid zone conguration. The heat
pump and heat strip DIP switches
are both set to the ON position in one
zone. Heat pump, heat strip, air con-
ditioner, and dehumidify operation
will be locked out in the affected zone.
E9 Invalid zone conguration. The dehu-
midier DIP switch and either the heat
pump or heat strip DIP switches are
set to the ON position in one zone.
Heat pump, heat strip, air condition-
er, and dehumidify operation will be
locked out in the affected zone.
In the unlikely event you experience a system failure, refer to the “SERVICE” section of the Operating
Instructions furnished with your unit.
Special Features:
● Auto Fan
● Stage Select (Two air conditioners/
heat pumps or models equipped with
two compressors)
● Programs 1 & 2
● Auxiliary Heat (heat pump models
only)
● Load Shed
● Automatic Generator Start (optional)
See Operating Instructions Manual
for more information on special fea-
ture.
LCD Error Code
When the system determines that one of
the faults listed below has occurred an
error code will be displayed in the LCD
for the zone in which the error occurred.
During normal operation, a blinking zone
number indicates a fault has occurred.
The error code is displayed in place of the
temperature set-point.
Error Code:
E1 Loss of communication between the
CCC 2 thermostat and all system
power module boards. System will
shut down.
E1 Loss of communication between the
CCC 2 thermostat and an individual
system power module board. The
LED will display error code E1 and
the zone number that lost communi-
cation. Any additional zones that lose
communication will blink in addition to
the current zone.
E2 Open circuit or out-of-range Indoor
Temperature Sensor. All heat, cool,
and dehumidify operation will be
locked out. Manual fan operation can
continue.