Troubleshooting CFX100W
28
9 Troubleshooting
Fault Possible cause Suggested remedy
Device does not
function, LED does
not glow.
Battery voltage is too
low.
Test the battery and charge it as needed.
The DC cable fuse is
defective.
Replace the DC fuse, see chapter
“Replacing the DC cable fuse” on
page 26.
No voltage present in
the AC voltage socket.
Try using another plug socket.
The AC fuse is
defective.
Replace the AC fuse, see chapter
“Replacing the AC fuse” on page 25.
The integrated mains
adapter is defective.
This can only be repaired by an
authorised repair centre.
The device does not
cool (power is
connected, “POWER”
LED is lit).
Defective compressor. This can only be repaired by an
authorised repair centre.
The device does not
cool (power is
connected, “POWER”
LED flashes orange,
display is switched
off).
Battery monitor is set
too high.
Select a lower battery monitor setting.
Battery voltage is too
low.
Test the battery and charge it as needed.
The display shows an
error message (e.g.
“Err1”) and the
appliance does not
cool.
The appliance has
switched off due to an
internal fault.
This can only be repaired by an
authorised repair centre.
CFX-100W--O-EN-AUS.book Seite 28 Donnerstag, 13. Juli 2017 10:12 10