CFX Cleaning and maintenance
21
I
7.14 Replacing the light PCB
1. Disconnect the power supply to the device.
2. Pry out the transparent cover with a screwdriver (fig. 9 1, page 5).
3. Unscrew the PCB mounting screws (fig. 9 2, page 5).
4. Pull out the plug from the PCB (fig. 9 3, page 5).
5. Replace the defective light PCB with a new one.
6. Fit new PCB using reverse of removal instructions.
7. Press the transparent cover back into the housing.
8. Reconnect the power supply to the device.
8 Cleaning and maintenance
A
➤ Occasionally clean the cooling device interior and exterior with a damp cloth.
➤ Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
NOTE – Internal DC fuse
There is an additional DC fuse inside the device (Automotive standard
blade fuse, 10 A). This fuse can only be replaced by an authorised repair
centre.
NOTICE! Damage hazard
• Never clean the cooling device under running water or in dish water.
• Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooling device.
DometicCFX28-CFX50_OPM_4445103579_EMEA16_202x-xx-xx.book Seite 21 Dienstag, 28. September 2021 4:09 16