6.1 Battery monitor
The cooling device is equipped with an electronic device to protect against revers-
ing the polarity when connecting to a battery. To protect the battery, the cooling
device switches off automatically if the voltage is insufficient (see following table).
Devices without TEC control
Devices with TEC control
7 Installing the cooling unit
!
7.1 Tools required
For installation and assembly, you will need the following tools:
•Drill
Screwdriver
Open-ended spanner: 16 mm, 19 mm and 21 mm
Sealant and PUR foam
Cable, cable lugs and cable clips
•Ester oil
Connection voltage Switch-off voltage Restart voltage
12 V
10.4 V 11.7 V
24 V
22.8 V 24.2 V
Connection voltage Switch-off voltage Restart voltage
12 V
10.7 V 13.0 V
24 V
22.0 V 26.0 V
WARNING!
The installation may only be performed by a qualified technician.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 18 Tuesday, May 4, 2021 7:24 PM