Coldmachine Technical data
31
Unusual noises
13 Technical data
Fault Possible cause Remedy
Loud humming A component of the refrigerant circuit can-
not move freely (lies against the wall)
Bend the component
carefully away from the
obstruction
Foreign body jammed between the
cooling device and the wall
Remove the foreign body
Fan noise (if installed) Clean the fan blades
50 54 55
Max. cooling area
contents:
80 litres 130 litres
Connection voltage: 12 Vg or 24 Vg
Power consumption: 35 – 40 W, depending on the evaporator type
Coolant quantity: 28 g 35 g
CO2 equivalent: 0.040 t 0.050 t
Global warming
potential (GWP):
1430
Dimensions
(W x H x D) in mm:
315 x 140 x 170 386x155x130 220x160x220
Weight: 3.74 kg 6.0 kg 6.5 kg
84 85 86
Max. cooling area
contents:
250 litres
Connection voltage: 12 Vg or 24 Vg
Coolant quantity: 45 g
CO2 equivalent: 0.064 t
Global warming
potential (GWP):
1430
Dimensions
(W x H x D) in mm:
386x155x130 220x155x220 220x230x177
Weight: 6.0 kg 6.0 kg 6.5 kg
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 31 Tuesday, May 4, 2021 7:24 PM