Disposal FreshLight
18
10 Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the
influence that their activities (manufacturing, products, services, etc.) have on the
environment.
The procedures to be followed to identify significant environmental impact must take
the following factors into account:
use of raw materials and natural resources
atmospheric emissions
discharge of liquids
waste management and recycling
contamination of the soil
Low air output The air intake section is clogged up. Remove any leaves and other dirt
from the ventilation grilles of the
roof air conditioner.
The blower is defective. Contact an authorised workshop.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
Clean the drainage openings for
condensation water.
The seals are damaged. Contact an authorised workshop.
Roof air
conditioner does
not switch on.
No supply voltage (230 Vw) connected. Check the power supply.
The voltage is too low (under 200 V).
The voltage converter is defective.
Contact an authorised workshop.
One of the temperature sensors is
defective.
The electrical fuse of the power supply is
too low.
Check the electrical fuse of the
power supply.
Roof air
conditioner does
not switch off.
One of the temperature sensors is
defective.
Contact an authorised workshop.
The electrical fuse of the power supply is
too low.
Check the electrical fuse of the
power supply.