11
5.1
5.3
5.4
55..00
5.2
INSTRUCTION for USE
Leakage Detection
The electronics carry out a leakage test after every defrosting period
(every 24 hrs) by measuring the temperature at the evaporator by means of
a second sensor.
If the electronics detect a leak, the miniBar is automatically switched off .
The LED for the interior lighting changes after approx. 10 secs. to a conti-
nuous flashing. (The LED of the door-opening control flashes synchronous-
ly , if available.)
Automatic Defrost Function
The first defrosting phase commences 39 hours after the initial operation
and lasts for two hours.
After this, the device operates for 22 hours at a time, followed by a
defrosting period of 2 hours .
The ice layer must never be removed using force, nor
must the defrosting process ever be accelerated using a
heater.
Initial Operation
The device must be plugged into a properly
earthed socket.
The miniBar starts automatically with a self-
test. If the electronics do not detect any
fault, the LED for the interior lighting illumi-
nates for 2 seconds after approximately 10
seconds. If a fault is detected, the illumina-
tion changes to a continuous flashing light.
If this occurs, please consult your authorised
Customer Service.
The miniBar achieves its operating
temperature after several hours.
The miniBar
operates silently !
Temperature Control
The miniBar is fitted with an electronic
temperature control which works fully
automatically.
A preadjustment of 3° or 5° is possible by
means of an optional remote control.
YELLOW = 3°C
BLUE = 5°C