KRA Refrigeration Systems
(with R-404A refrigerant)
Installation, Operation & Maintenance Manual
KRA 433X
Air-and-Water-Cooled
KRA 450X
Air-and-Water-Cooled
Dometic Marine
Rev. 20180906
L-3571 English
P/N: 340161
KRA 433X
Water-Cooled-Only

Questions and Answers

  • J
    Joshua PhillipsAug 16, 2025
    Why is my Dometic Marine Equipment running but not cooling?
    • J
      joshuabennettAug 16, 2025
      If your Dometic Marine Equipment's compressor and fan (or pump) are running, but the box isn't cooling, it could be due to several reasons. First, check the fan and coil for proper airflow and ensure adequate ventilation, especially if the temperature exceeds 100°F/38°C. Also, inspect the seawater system for proper flow. Other potential causes include an incorrectly set Thermostatic Expansion Valve (TXV), which requires a technician's attention, or a low refrigerant charge, which necessitates checking for leaks and recharging the system with R-404A. A mechanical failure of the TXV could also be the culprit, requiring diagnosis and replacement by a technician.
  • M
    Michael ChungAug 19, 2025
    How to troubleshoot a Dometic KRA 433X 1161 Marine Equipment when compressor and fan do not run?
    • D
      David HowardAug 19, 2025
      If the compressor and fan (or pump) of your Dometic Marine Equipment do not run, start by checking if the circuit breaker is off and turn it on or reset it if necessary. Then, check the thermostat and ensure it is set for a cooler setting. Also, the issue might be related to a High/Low pressure switch; in this case, check the Dometic control for fault codes LP or 1A and consider calling a technician.
  • K
    Kent PottsAug 23, 2025
    What to do if Dometic Marine Equipment fan runs but compressor doesn't?
    • V
      vsullivanAug 23, 2025
      If your Dometic Marine Equipment fan or pump operates, but the compressor doesn't (and the high-pressure switch or thermal overload has tripped), check for low voltage to the unit, as the Klixon may be open. Also, check the fan and coil for proper airflow to ensure adequate condenser cooling. If the temperature is above 100°F/38°C, ventilate the area. Inspect the seawater system as well. The problem might be related to a High/Low pressure switch, requiring you to check the Dometic control for fault codes LP or 1A and consult a technician.
  • S
    Seth ChambersAug 27, 2025
    How to fix Dometic Marine Equipment with unlit displays?
    • M
      Maxwell SweeneyAug 27, 2025
      If the displays on your Dometic Marine Equipment are not lit, check the circuit breaker first to ensure that power is connected. Then, inspect all connections for any looseness. Also, verify that the voltage input of the control is correct. If these steps do not resolve the issue, consult a technician.
  • H
    hcooperAug 30, 2025
    Why does my Dometic KRA 433X 1161 Marine Equipment freeze and stop cooling?
    • A
      Anna AndradeAug 31, 2025
      If your Dometic Marine Equipment system starts to cool, but stops as plates freeze, check the sight glass for moisture. Yellow indicates moisture; green indicates a dry system.
  • B
    Brooke MeyerSep 3, 2025
    How to improve cooling of Dometic KRA 433X 1161 box?
    • C
      Cole SanchezSep 3, 2025
      If your Dometic Marine Equipment is not cooling the box sufficiently, turn the unit OFF and defrost it according to the instructions in 'Defrosting'. Ensure that the thermostat is properly set. Minimize the amount of time the box is open to prevent warm air from entering. If you've recently added many warm items, allow the unit time to cool them. Replace any poor seals and ensure there's a drain plug. Other potential issues include an improperly set Thermostatic Expansion Valve (TXV), low refrigerant charge, high condensing temperature (introduce cooler air into the compartment), improperly mounted temperature sensor, moisture in the system, or inadequate design.
  • J
    jasonwatsonSep 7, 2025
    What causes Dometic KRA 433X 1161 compressor to run but seawater pump to fail?
    • T
      Theresa AlvaradoSep 7, 2025
      If the compressor operates, but the seawater pump doesn’t for your Dometic Marine Equipment, turn on or reset the pump breaker. Check the pump relay and pump relay trigger.
  • M
    Michael PowellNov 11, 2025
    What to do if my Dometic KRA 433X 1161 unit does not run?
    • Y
      Yvonne PalmerNov 11, 2025
      If your Dometic Marine Equipment unit isn't running, first, ensure that the power is turned ON at the panel and check if the thermostat display illuminates. If the display remains off, the issue might stem from a disconnected power supply or a blown circuit breaker, so check the breaker. If the display is on, verify the thermostat settings and confirm the correct voltage at the thermostat. Should the thermostat display a fault code, consult the 'Thermostat Display Error Messages (digital Dometic control)'. If the thermostat continues to malfunction or display a fault code, consider replacing it. Also, check for loose or missing wiring connections behind the control and in the electrical box. Ensure that there are no additional in-line cut-off switches. Other potential causes include start ...

Summary

Safety Instructions

Read This Manual Before Proceeding

Essential information for proper installation, operation, and maintenance of KRA refrigeration systems.

Safety Guidelines

Guidelines for qualified technicians and adherence to local codes for safe installation and service.

Safe Handling of Refrigerants

Precautions and warnings for handling R-404A refrigerant, emphasizing environmental responsibility.

Refrigeration Basics

System Components

System Installation

Important Safety Considerations

Critical safety warning regarding electrical shock hazards during installation.

Installing the Refrigeration System

Sight Glass;Moisture Indicator

Thermostat

Refrigerant Charge

Refrigeration System Operation

KRA Refrigeration Start-Up Check List

Pre-operation checklist ensuring all connections and components are secure and correct.

Starting The System

Step-by-step procedure for starting the refrigeration system after installation.

Thermostat Operation

Details on operating the Dometic control for the refrigeration system.

Thermostat Operation

Operating The Dometic Control

Guide to powering on the system and navigating the Dometic control display interface.

Parameter Programming

Procedure for accessing and setting various operational parameters via the thermostat control.

Servicing Your Refrigeration System

Recharging The System

Steps for system shutdown, evacuation, and charging with R-404A refrigerant.

Servicing Your Refrigeration System

Adjusting the TXV

Procedure for qualified technicians to make slight adjustments to the TXV for superheat control.

User Maintenance

Troubleshooting Guide

Figures & Wiring Diagrams

Figure 11: Wiring Diagram for KRA 433 X Unit with 1 Box

Wiring diagram for a KRA 433X unit connected to a single box.

Figure 12: Wiring Diagram for KRA 433 X Unit with 2 Boxes

Wiring diagram for a KRA 433X unit connected to two boxes.

Dometic KRA 433X 1161 Specifications

General IconGeneral
CategoryMarine Equipment
ModelKRA 433X 1161
BrandDometic
Energy SourceElectric
Frequency50/60 Hz
Voltage230V