KRA Refrigeration Systems
(with R-404A refrigerant)
Installation, Operation & Maintenance Manual
KRA 433X
Air-and-Water-Cooled
KRA 450X
Air-and-Water-Cooled
Dometic Marine
Rev. 20180906
L-3571 English
P/N: 340161
KRA 433X
Water-Cooled-Only

Questions and Answers

  • M
    Maureen GentryAug 16, 2025
    Why is my Dometic KRA 433X running but not cooling?
    • R
      Rebecca PerezAug 16, 2025
      If your Dometic Marine Equipment's compressor and fan (or pump) are running, but the box isn't cooling, it could be due to several reasons. First, check the fan and coil for proper airflow and ensure adequate ventilation, especially if the temperature exceeds 100°F/38°C. Also, inspect the seawater system for proper flow. Other potential causes include an incorrectly set Thermostatic Expansion Valve (TXV), which requires a technician's attention, or a low refrigerant charge, which necessitates checking for leaks and recharging the system with R-404A. A mechanical failure of the TXV could also be the culprit, requiring diagnosis and replacement by a technician.
  • R
    richard07Aug 20, 2025
    How to troubleshoot a Dometic KRA 433X Marine Equipment when compressor and fan do not run?
    • B
      Brittany FrenchAug 20, 2025
      If the compressor and fan (or pump) of your Dometic Marine Equipment do not run, start by checking if the circuit breaker is off and turn it on or reset it if necessary. Then, check the thermostat and ensure it is set for a cooler setting. Also, the issue might be related to a High/Low pressure switch; in this case, check the Dometic control for fault codes LP or 1A and consider calling a technician.
  • R
    robertsellersAug 23, 2025
    What to do if Dometic Marine Equipment fan runs but compressor doesn't?
    • M
      Martin WilsonAug 23, 2025
      If your Dometic Marine Equipment fan or pump operates, but the compressor doesn't (and the high-pressure switch or thermal overload has tripped), check for low voltage to the unit, as the Klixon may be open. Also, check the fan and coil for proper airflow to ensure adequate condenser cooling. If the temperature is above 100°F/38°C, ventilate the area. Inspect the seawater system as well. The problem might be related to a High/Low pressure switch, requiring you to check the Dometic control for fault codes LP or 1A and consult a technician.
  • M
    Michael AlexanderAug 27, 2025
    How to fix Dometic Marine Equipment with unlit displays?
    • L
      Lisa GordonAug 27, 2025
      If the displays on your Dometic Marine Equipment are not lit, check the circuit breaker first to ensure that power is connected. Then, inspect all connections for any looseness. Also, verify that the voltage input of the control is correct. If these steps do not resolve the issue, consult a technician.
  • J
    Joseph EspinozaAug 31, 2025
    Why does my Dometic KRA 433X Marine Equipment freeze and stop cooling?
    • P
      Parker HendersonAug 31, 2025
      If your Dometic Marine Equipment system starts to cool, but stops as plates freeze, check the sight glass for moisture. Yellow indicates moisture; green indicates a dry system.
  • A
    Albert SheltonSep 3, 2025
    How to improve cooling of Dometic KRA 433X box?
    • P
      Patricia HillSep 4, 2025
      If your Dometic Marine Equipment is not cooling the box sufficiently, turn the unit OFF and defrost it according to the instructions in 'Defrosting'. Ensure that the thermostat is properly set. Minimize the amount of time the box is open to prevent warm air from entering. If you've recently added many warm items, allow the unit time to cool them. Replace any poor seals and ensure there's a drain plug. Other potential issues include an improperly set Thermostatic Expansion Valve (TXV), low refrigerant charge, high condensing temperature (introduce cooler air into the compartment), improperly mounted temperature sensor, moisture in the system, or inadequate design.
  • A
    Ashley FloresSep 7, 2025
    What causes Dometic KRA 433X compressor to run but seawater pump to fail?
    • L
      Lisa FloresSep 7, 2025
      If the compressor operates, but the seawater pump doesn’t for your Dometic Marine Equipment, turn on or reset the pump breaker. Check the pump relay and pump relay trigger.
  • B
    Brian FowlerNov 11, 2025
    What to do if my Dometic KRA 433X Marine Equipment unit does not run?
    • C
      christopherdouglasNov 12, 2025
      If your Dometic Marine Equipment unit isn't running, first, ensure that the power is turned ON at the panel and check if the thermostat display illuminates. If the display remains off, the issue might stem from a disconnected power supply or a blown circuit breaker, so check the breaker. If the display is on, verify the thermostat settings and confirm the correct voltage at the thermostat. Should the thermostat display a fault code, consult the 'Thermostat Display Error Messages (digital Dometic control)'. If the thermostat continues to malfunction or display a fault code, consider replacing it. Also, check for loose or missing wiring connections behind the control and in the electrical box. Ensure that there are no additional in-line cut-off switches. Other potential causes include start ...

Summary

Safety Instructions

Read This Manual Before Proceeding

Emphasizes understanding the manual for proper operation and safety.

Recognize Safety Symbols, Words and Labels

Explains the importance and meaning of safety symbols and labels used in the manual.

Safety Guidelines

Provides essential rules for safe installation and servicing of the refrigeration system.

Safe Handling of Refrigerants

Details precautions and regulations for handling refrigerants like R-404A.

System Installation

Important Safety Considerations

Highlights the electrical shock hazard and the need for proper grounding.

Installing the Refrigeration System

Condensing Unit

Details installation location requirements, temperature limits, and airflow/water flow needs for condensing units.

Refrigeration System Operation

KRA Refrigeration Start-Up Check List

Lists essential checks to perform before starting the refrigeration system.

Starting the System

Step-by-step guide for initiating operation of the refrigeration system.

Servicing Your Refrigeration System

Recharging the System

Outlines when and how to recharge the system after repairs or if charge is lost.

Evacuate Refrigerant

Details the steps for evacuating refrigerant from the system using manifold gauges and a vacuum pump.

Charging the System

Provides instructions for weighing in refrigerant and typical operating pressures.

User Maintenance

Troubleshooting Guide

Dometic KRA 433X Series Specifications