KRA Refrigeration Systems
(with R-404A refrigerant)
Installation, Operation & Maintenance Manual
KRA 433X
Air-and-Water-Cooled
KRA 450X
Air-and-Water-Cooled
Dometic Marine
Rev. 20180906
L-3571 English
P/N: 340161
KRA 433X
Water-Cooled-Only

Questions and Answers

  • J
    jasonsteeleAug 16, 2025
    Why is my Dometic KRA running but not cooling?
    • B
      Bethany HuffmanAug 16, 2025
      If your Dometic Marine Equipment's compressor and fan (or pump) are running, but the box isn't cooling, it could be due to several reasons. First, check the fan and coil for proper airflow and ensure adequate ventilation, especially if the temperature exceeds 100°F/38°C. Also, inspect the seawater system for proper flow. Other potential causes include an incorrectly set Thermostatic Expansion Valve (TXV), which requires a technician's attention, or a low refrigerant charge, which necessitates checking for leaks and recharging the system with R-404A. A mechanical failure of the TXV could also be the culprit, requiring diagnosis and replacement by a technician.
  • J
    Joseph LyonsAug 19, 2025
    How to troubleshoot a Dometic KRA when compressor and fan do not run?
    • T
      thomasrhondaAug 19, 2025
      If the compressor and fan (or pump) of your Dometic Marine Equipment do not run, start by checking if the circuit breaker is off and turn it on or reset it if necessary. Then, check the thermostat and ensure it is set for a cooler setting. Also, the issue might be related to a High/Low pressure switch; in this case, check the Dometic control for fault codes LP or 1A and consider calling a technician.
  • K
    kriosAug 23, 2025
    What to do if Dometic KRA Marine Equipment fan runs but compressor doesn't?
    • B
      brandonbrennanAug 23, 2025
      If your Dometic Marine Equipment fan or pump operates, but the compressor doesn't (and the high-pressure switch or thermal overload has tripped), check for low voltage to the unit, as the Klixon may be open. Also, check the fan and coil for proper airflow to ensure adequate condenser cooling. If the temperature is above 100°F/38°C, ventilate the area. Inspect the seawater system as well. The problem might be related to a High/Low pressure switch, requiring you to check the Dometic control for fault codes LP or 1A and consult a technician.
  • E
    Emily MontgomeryAug 27, 2025
    How to fix Dometic Marine Equipment with unlit displays?
    • R
      Richard YoungAug 27, 2025
      If the displays on your Dometic Marine Equipment are not lit, check the circuit breaker first to ensure that power is connected. Then, inspect all connections for any looseness. Also, verify that the voltage input of the control is correct. If these steps do not resolve the issue, consult a technician.
  • C
    chavezalexandriaAug 31, 2025
    Why does my Dometic KRA Marine Equipment freeze and stop cooling?
    • R
      robertedwardsAug 31, 2025
      If your Dometic Marine Equipment system starts to cool, but stops as plates freeze, check the sight glass for moisture. Yellow indicates moisture; green indicates a dry system.
  • M
    Megan BoothSep 3, 2025
    How to improve cooling of Dometic KRA Marine Equipment box?
    • N
      Nicole SanfordSep 4, 2025
      If your Dometic Marine Equipment is not cooling the box sufficiently, turn the unit OFF and defrost it according to the instructions in 'Defrosting'. Ensure that the thermostat is properly set. Minimize the amount of time the box is open to prevent warm air from entering. If you've recently added many warm items, allow the unit time to cool them. Replace any poor seals and ensure there's a drain plug. Other potential issues include an improperly set Thermostatic Expansion Valve (TXV), low refrigerant charge, high condensing temperature (introduce cooler air into the compartment), improperly mounted temperature sensor, moisture in the system, or inadequate design.
  • V
    Virginia MasonSep 7, 2025
    What causes Dometic KRA compressor to run but seawater pump to fail?
    • C
      Carrie CraigSep 8, 2025
      If the compressor operates, but the seawater pump doesn’t for your Dometic Marine Equipment, turn on or reset the pump breaker. Check the pump relay and pump relay trigger.
  • M
    miguelmcguireNov 11, 2025
    What to do if my Dometic KRA unit does not run?
    • R
      Renee WyattNov 11, 2025
      If your Dometic Marine Equipment unit isn't running, first, ensure that the power is turned ON at the panel and check if the thermostat display illuminates. If the display remains off, the issue might stem from a disconnected power supply or a blown circuit breaker, so check the breaker. If the display is on, verify the thermostat settings and confirm the correct voltage at the thermostat. Should the thermostat display a fault code, consult the 'Thermostat Display Error Messages (digital Dometic control)'. If the thermostat continues to malfunction or display a fault code, consider replacing it. Also, check for loose or missing wiring connections behind the control and in the electrical box. Ensure that there are no additional in-line cut-off switches. Other potential causes include start ...

Summary

SAFETY INSTRUCTIONS

General Safety Guidelines

Provides essential safety rules for installation, operation, and maintenance.

Refrigerant Handling Safety

Details safety precautions for handling R-404A refrigerant.

SYSTEM INSTALLATION PROCEDURES

Electrical Safety and Tools

Highlights electrical safety precautions and lists necessary installation tools.

INSTALLATION GUIDELINES

Condensing Unit Placement and Operation

Details the placement and operating conditions for the condensing unit.

Refrigerant Charge Information

Discusses refrigerant charge, system sensitivity, and repair procedures.

REFRIGERATION SYSTEM OPERATION

Pre-Start-Up Checklist

Provides a comprehensive checklist before starting the refrigeration system.

System Start-Up Procedure

Outlines the step-by-step procedure for starting the refrigeration system.

SERVICING YOUR REFRIGERATION SYSTEM

Refrigerant and Charging

Discusses R-404A refrigerant, charging, evacuation, and system shutdown.

SERVICING AND USER MAINTENANCE

TROUBLESHOOTING GUIDE

FIGURES AND DIAGRAMS

KRA 433 X 2-Box Installation Diagram

Detailed installation diagram for a KRA 433X system with two fish boxes.

KRA 450 X 3-Box Installation Diagram

Detailed installation diagram for a KRA 450X system with three fish boxes.

KRA 433 X 1-Box Wiring Diagram

Illustrates the wiring schematic for a KRA 433X unit connected to one box.

KRA 433 X 2-Box Wiring Diagram

Shows the wiring schematic for a KRA 433X unit connected to two boxes.

KRA 450 X 1-Box Wiring Diagram

Illustrates the wiring schematic for a KRA 450X unit connected to one box.

KRA 450 X 3-Box Wiring Diagram

Shows the wiring schematic for a KRA 450X unit connected to three boxes.

Dometic KRA Series Specifications

General IconGeneral
TypeRefrigerator
SeriesKRA
Voltage12V/24V DC
CapacityVaries by model (refer to specific model specifications)
Energy ConsumptionVaries by model and usage conditions
RefrigerantR134a
WeightVaries by model (refer to specific model specifications)
Dimensions (H x W x D)Varies by model (refer to specific model specifications)
InstallationBuilt-in

Related product manuals