MSG150 Operating the MagicSafe MSG150
EN
17
9 Operating the MagicSafe MSG150
To avoid false alarms caused by cooking, using deodorants, heavy smoking and alcohol consump-
tion, the vehicle should be ventilated thoroughly before retiring to bed and then the gas detector
should be switched on.
Switching on the MSG150 as a single device or in combination with the external siren
(ref. no. 9101600008)
Insert the 12/24 Vg plug in a socket or switch on the gas detector with the RV-AMP-SW
auxiliary switch.
An acoustic signal sounds and the green LED (fig. 8 1, page 5) flashes for approx. 10 minutes.
During this time the gas detector conducts a system test and the sensor is brought to operating
temperature.
If an alarm occurs, an acoustic signal sounds over the internal siren and the red LED (fig. 8 3,
page 5) glows. If the external siren is connected, an additional acoustic signal sounds over the
external siren.
To interrupt the internal alarm, press the pushbutton (fig. 8 4, page 5).
No. in
fig. 8,
page 5
description
1 Green LED
The green LED flashes for approx. 10 minutes after the gas detector has been
connected to a voltage supply or switched on with the RV-AMP-SW auxiliary
switch. While the LED is flashing, the sensor is brought to the operating
temperature.
When the green LED glows constantly, the gas detector is ready for operation.
2 Orange LED:
The orange LED glows if a fault occurs.
3 Red LED (alarm)
The red LED flashes if an alarm has been triggered.
In addition to this, a siren sounds an alarm signal.
(See also chapter “Alarm” on page 18.)
4 Pushbutton
This pushbutton is a test button and also mutes the system.
Test pushbutton
Press this pushbutton once a month or after extended periods of disuse to
check the system is functioning.
The orange and red LEDs flash and a siren sounds.
Mute switch
Press this pushbutton if you wish to switch off the sound during an alarm.
The red LED continues flashing and a brief signal sounds every 45 seconds.
Then the system is armed again.
MSG150-IO-16s.book Seite 17 Donnerstag, 11. August 2016 12:02 12

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic MagicSafe MSG150 and is the answer not in the manual?

Dometic MagicSafe MSG150 Specifications

General IconGeneral
BrandDometic
ModelMagicSafe MSG150
CategoryOther
LanguageEnglish

Related product manuals