EasyManuals Logo

Dometic MCS T6 User Manual

Dometic MCS T6
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
EN
MCS T6, MCS T12, MCS T16 Troubleshooting
29
Failsafe Level 1
All actions in level 0 plus all other faults detected but not indicated.
The system shuts down for 2 min or until the fault is cleared, whatever is longer.
The system will restart if the fault is cleared.
Failsafe Level 2
All actions same as level 0 and 1. Faults are indicated.
The system shuts down for 2 min or until the fault is cleared, whatever is longer.
Failsafe Level 3
All actions the same as level 0, 1 and 2.
The system shuts down for 2 min or until the fault is cleared, whatever is longer.
The system will lockout after four consecutive “HPF” or “LPF” faults.
To clear the lockout:
Pressing the Power Button once to Off Mode.
Pressing the Power Button again to On Mode.
MCS-6-12-16--O-West.book Seite 29 Dienstag, 14. November 2017 11:28 11

Other manuals for Dometic MCS T6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic MCS T6 and is the answer not in the manual?

Dometic MCS T6 Specifications

General IconGeneral
BrandDometic
ModelMCS T6
CategoryAir Conditioner
LanguageEnglish

Related product manuals