OPERATING INSTRUCTIONS
GAS, AC AND DC OPERATION
LP gas operation
Before starting the refrigerator, open the shutoff valve of the
gas bottle (check that there is enough gas). Open any on-
board shutoff valve.
Start the refrigerator by turning turn knob A to
position (GAS).
Turn the thermostat knob B to position 4.
Press and hold button C and push button D for the
piezo igniter several times to light the burner.
This can be observed on the ame indicator E.
When the ame is lit, the red indicator is in the
green eld. (ON).
After the gas is lit keep button C pressed for 10 s.
Release the button and check that the red indicator
is in the green eld, (ON).
Note! After changing an LP tank, or after a long shut off pe-
riod, the gas line is likely to be lled with air. You may have
to repeat the lighting procedure several times to purge the air
out of the gas lines.
230-240 V AC OPERATION
Before operating the refrigerator, check that the voltage
stated on the data plate is the same as the main voltage in use.
Check to be sure that the power cord is properly
connected to the power supply.
Turn the knob A to the position marked “AC” for
230-240 volt AC operation.
Turn the thermostat knob B to position 4.
12 V DC OPERATION
Only operate your refrigerator on 12 V DC when the engine
of the vehicle is running - otherwise your battery will soon be
discharged.
Turn the knob A to the position marked “DC” for
12 V DC operation.
Note that there is no thermostat function on 12 V
DC operation, the refrigerator works continuously.
1.
2.
3.
4.
1.
2.
3.
Whilst mobile:
- Do not operate the refrigerator on LP gas.
- Turn off the gas bottle.
WARNING
!
REGULATING THE TEMPERATURE
The refrigerator is equipped with a thermostat that can be
adjusted by turning the knob B to different setting to maintain
the desired cabinet temperature.
Gas operation
At “OFF, the thermostat closes its main valve and the
burner runs continuously at the bypass rate, just enough to
keep the burner lit.
At “MAX”, the thermostat allows the burner to remain on
high ame continuously.
AC operation (230-240 V AC)
At “OFF, the contacts in the thermostat are open and the
heating elements are off.
At “MAX”, the heating element is “ON” continuously.
Lowest cabinet and freezer temperatures are obtained at
this setting.
The thermostat can be adjusted between “MAX” and “OFF”
to obtain the desired cabinet temperature. The closer the knob
is to “MAX” - the colder the cabinet temperature. The closer
the knob is to “OFF” - the warmer the cabinet temperature.
When the thermostat reaches the set temperature, it will cut
the burner back to bypass or, in electric operation (230-
240 V AC), shut off the heating element. The setting of the
thermostat is not critical, but we recommend it be adjusted
to maintain a dry frost on the cooling ns. Adjust the ther-
mostat knob closer to “MAX” when the outside temperature
becomes warm.
TURNING OFF THE REFRIGERATOR
To shut off the refrigerator turn the knob A to
“OFF”.
If the refrigerator will not be in operation for a
period of weeks, it should be emptied, defrosted,
cleaned and the door left ajar. Use the travel catch
to hold in this position. The ice tray should also be
dried and kept outside the cabinet.

Other manuals for Dometic RM2350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2350 and is the answer not in the manual?

Dometic RM2350 Specifications

General IconGeneral
Door TypeReversible
TypeAbsorption
Interior LightYes
RefrigerantAmmonia
Energy SourceAC/DC

Related product manuals