MAINTENANCE & SERVICE
7. Verify that the burner jet slots are centered under
the ue tube and that the thermocouple is posi-
tioned properly.
8. Be sure to check the burner ame for proper ap-
pearance. The ame should be clear blue over
the slots of the burner.
9. Check the electrode for proper location and gap.
Adjustments may be made with needle nose pli-
ers if necessary.
10. Turn on the manual gas shut off valve.
11. Examine all ttings for leaks. (Use a commer-
cial non-corrosive bubble solution.)
12. Connect the 120 VAC power cord.
13. RM2510: Reconnect / turn on the 12 VDC
power.
14. Check LP gas safety shutoff.
To keep the refrigerator working properly, a quali-
ed service technician should, at least once a year,
inspect the connections, the control system, the LP
gas pressure, and the ue bafe.
PERIODIC MAINTENANCE
To be performed by a qualied service technician
only.
CHECKING THE LP GAS CONNECTIONS
1. Check all connections in the LP gas system (at
the back of the refrigerator) for gas leaks. The
LP gas supply must be turned on.
2. Apply an approved leak detection solution to all
LP gas connections. The appearance of bubbles
indicates a leak and should be repaired imme-
diately!
CLEANING THE BURNER
1. Turn off the refrigerator.
2. Unplug the power cord from the 120 VAC outlet.
3. RM2510: Disconnect the wires or shut off the 12
VDC power supply to the refrigerator.
4. Turn off the manual shut off valve.
5. Remove cover from burner housing.
6. Clean the burner tube with a brush. Blow out the
burner with compressed air.
FIRE OR EXPLOSION HAZARD. Never use an
open ame to check for gas leaks. Failure to
obey this warning could cause a re or explo-
sion resulting in death or serious injury.
FIRE AND INHALATION HAZARD. If the re-
frigerator stops working -or- if it emits an am-
monia smell, immediately turn the refrigerator
off, leave the vicinity, and contact a Service
Center.
A high concentration of ammonia refriger-
ant could cause an inhalation hazard, could
cause chemical burns to the skin and eyes,
and could cause a re resulting in death or
serious injury.
FIRE HAZARD. Never use a wire or pin to clear
obstructions from the burner jet as damage
will occur. Do not attempt to adjust the burner
jet. Failure to obey this warning could cause
a re resulting in death or serious injury.
Clear blue color
of flame
Electrode
Burner tube
1/8” to 3/16
(3-5 mm)
Slots Centered
Under Flue Tube

Other manuals for Dometic RM2510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2510 and is the answer not in the manual?

Dometic RM2510 Specifications

General IconGeneral
BrandDometic
ModelRM2510
CategoryRefrigerator
LanguageEnglish

Related product manuals