EasyManua.ls Logo

Dometic RTX2000 - P.02 Temperature Display Unit; P.05 Tilt Sensor Calibration

Dometic RTX2000
240 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
EN
RTX1000/2000, SPX1200T Configuring the system software
7.3 P.02: Unit for temperature display
The system can display the room temperature in °C or °F.
Switch to configuration mode (chapter “Entering and exiting configuration
mode” on page 13).
The display shows “P.01” and the symbol flashes.
Press the or button to select the menu item P.02.
The display shows “P.02” and the symbol lights up.
Press the button to change the setting.
The code for the current setting is displayed:
0: °C
1: °F
Use the or button to select the desired temperature unit.
Press the button to save the setting.
The set value is saved and is then applied when the system is restarted.
You are then returned to the menu and can select another menu item by
pressing the or button.
7.4 P.05: Tilt sensor
The electronics of the system prevents that the system is switched on when the
vehicle is parked at a slope. Since some vehicles‘ roof already is tilted, the tilt
sensor has to calibrated to the zero setting before first use.
Park the vehicle on a level place.
Switch to configuration mode (chapter “Entering and exiting configuration
mode” on page 13).
The display shows “P.01” and the symbol flashes.
Press the or button to select the menu item P.05.
The display shows “P.05”.
Press the button to change the setting.
The code for the current setting is displayed.
Use the or button to select “1”.
Press the button to save the setting.
The set value is saved and is then applied when the system is restarted.
You are then returned to the menu and can select another menu item by
pressing the or button.