Troubleshooting TEC60EV
24
11 Troubleshooting
Fault Cause Remedy
The control panel
does not come on
when the on/off
switch is pressed.
Starter battery is flat.
➤ Charge the starter battery.
The fuse (if available) is blown.
➤ Contact an authorised workshop.
The starter does
not work when the
start button is
pressed.
Starter battery is flat.
➤ Charge the starter battery.
The main switch is at “0”.
➤ Set the main switch to “I” or “1”.
Internal board is damaged.
➤ Contact an authorised workshop.
Starter is not receiving any power.
The starter turns
but the generator
does not start.
No petrol.
➤ Fill up with petrol.
Too much oil in the engine.
➤ Drain the oil.
Spark plug is not receiving any power.
➤ Check the electric connections.
Carburettor is not receiving any petrol.
➤ Clean the carburettor.
Air intake is blocked.
➤ Check the air filter (see chapter
“Servicing the air filter” on
page 22).
Inverter is damaged.
➤ Contact an authorised workshop.
The generator
tends to go off.
Too much oil in the engine.
➤ Drain the oil.
Load is over 6,2 kW.
➤ Switch off the consumers.
Carburettor is not receiving any petrol.
➤ Clean the carburettor.
Air intake is blocked.
➤ Check the air filter (see chapter
“Servicing the air filter” on
page 22).
Inverter is damaged.
➤ Contact an authorised workshop.
Electromagnet (inverter) is blocked.
Air filter is dirty.
➤ Check the air filter (see chapter
“Servicing the air filter” on
page 22).
Fuel filter is dirty.
➤ Replace the fuel filter.
The generator is
running but does
not supply any
voltage.
Inverter is damaged.
➤ Check the output wiring
connection
➤ Contact an authorised workshop.
RPM too low.