EasyManua.ls Logo

Dometic TEC29 - Preparing Maintenance Work; Finishing Maintenance Work

Dometic TEC29
388 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
TEC29, TEC29LPG Servicing the generator
25
10.2 Preparing maintenance work
!
Switch the generator to no function with the main switch (fig. 4 1, page 5).
Disconnect the positive terminal of the supply battery.
Open the generator front door.
For maintenance work, you can take the generator out (fig. 5, page 5):
!
Undo the fastening screws (1).
Remove the mounting plate (2) with the generator from the housing (3).
10.3 Finishing maintenance work
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 5).
Close the generator front door.
CAUTION!
Note the following for all maintenance work:
The generator must not be running.
All the parts must be cooled down.
WARNING!
The mounting plate with generator is very heavy (> 40 kg) and could fall
out the housing if you take it out too far.
TEC29-B-16s.book Seite 25 Donnerstag, 21. Juli 2016 8:09 08